Metraipolis › archive › dc_88dbef3e828a

MEDA: Measurement-Efficient Disorder-Aware Majorana Zero Mode Detection in Realistic Devices — arXiv:2607.26208

Source
arXiv (en)
Original
https://arxiv.org/abs/2607.26208
License (as archived)
CC0-1.0
Archived
2026-10-19T06:39:44.286Z
SHA-256 of the archived text
dd51b4737d57f85a480d8797a30c277dc41ea327826e311084a5e8af13509159
Stable URL of this page
https://metraipolis.com/documento/dc_88dbef3e828a

How to cite

MEDA: Measurement-Efficient Disorder-Aware Majorana Zero Mode Detection in Realistic Devices — arXiv:2607.26208 — arXiv (en), https://arxiv.org/abs/2607.26208 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_88dbef3e828a (Metraipolis archive dc_88dbef3e828a, sha256 dd51b4737d57f85a480d8797a30c277dc41ea327826e311084a5e8af13509159)
BibTeX
@misc{dc88dbef3e828a,
  title = {MEDA: Measurement-Efficient Disorder-Aware Majorana Zero Mode Detection in Realistic Devices — arXiv:2607.26208},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2607.26208},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_88dbef3e828a; sha256 dd51b4737d57f85a480d8797a30c277dc41ea327826e311084a5e8af13509159},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2607.26208. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Fault-tolerant topological quantum computing relies on identifying Majorana zero modes (MZMs), but reliable detection in realistic devices remains challenging. Conventional topological indicators are inherently biased in finite, disordered systems, blurring the distinction between true MZMs and trivial states. Furthermore, attempts to map these indicators to real observables via machine learning require dense, expensive conductance measurements, creating a severe scaling bottleneck. To simultaneously address topological bias and measurement limitations, we present MEDA: a Measurement-Efficient, Disorder-Aware framework for MZM detection in realistic devices. MEDA maps sparse, practically obtainable observables directly to the robust periodic disorder invariant (PDI). Using a novel sparse parameter regime, MEDA reduces measurement volume by 10x while maintaining predictive quality, even in moderate to strong disorder regimes that limit conventional methods. Furthermore, MEDA naturally prioritizes input features consistent with the topological gap protocol, demonstrating strong physical interpretability.

Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-08-12 in quant-ph).
Categorie arXiv: Emerging Technologies (cs.ET) ; Mesoscale and Nanoscale Physics (cond-mat.mes-hall); Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2607.26208 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-19T06:30:54.846Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-08-12?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).