Metraipolis › archive › dc_88b5cb7a3085
Mechanical effects of MitraClip on leaflet stress and myocardial strain in functional mitral regurgitation - A finite element modeling study — Europe PMC PMID:31600276
- Source
- Europe PMC (en)
- Original
- https://europepmc.org/article/MED/31600276
- DOI
- 10.1371/journal.pone.0223472
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-10T09:51:02.512Z
- SHA-256 of the archived text
0501924278217ea2ce567e26c9cc5f20492edc1a2a84ff8590fa54c73f97285e- Stable URL of this page
https://metraipolis.com/documento/dc_88b5cb7a3085
How to cite
Mechanical effects of MitraClip on leaflet stress and myocardial strain in functional mitral regurgitation - A finite element modeling study — Europe PMC PMID:31600276 — Europe PMC (en), https://europepmc.org/article/MED/31600276 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_88b5cb7a3085 (Metraipolis archive dc_88b5cb7a3085, sha256 0501924278217ea2ce567e26c9cc5f20492edc1a2a84ff8590fa54c73f97285e)
BibTeX
@misc{dc88b5cb7a3085,
title = {Mechanical effects of MitraClip on leaflet stress and myocardial strain in functional mitral regurgitation - A finite element modeling study — Europe PMC PMID:31600276},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/31600276},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_88b5cb7a3085; sha256 0501924278217ea2ce567e26c9cc5f20492edc1a2a84ff8590fa54c73f97285e},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/31600276. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Purpose: MitraClip is the sole percutaneous device approved for functional mitral regurgitation (MR; FMR) but MR recurs in over one third of patients. As device-induced mechanical effects are a potential cause for MR recurrence, we tested the hypothesis that MitraClip increases leaflet stress and procedure-related strain in sub-valvular left ventricular (LV) myocardium in FMR associated with coronary disease (FMR-CAD). Methods: Simulations were performed using finite element models of the LV + mitral valve based on MRI of 5 sheep with FMR-CAD. Models were modified to have a 20% increase in LV volume (↑LV_VOLUME) and MitraClip was simulated with contracting beam elements (virtual sutures) placed between nodes in the center edge of the anterior (AL) and posterior (PL) mitral leaflets. Effects of MitraClip on leaflet stress in the peri-MitraClip region of AL and PL, septo-lateral annular diameter (SLAD), and procedure-related radial strain (Err) in the sub-valvular myocardium were calculated. Results: MitraClip increased peri-MitraClip leaflet stress at end-diastole (ED) by 22.3±7.1 kPa (p<0.0001) in AL and 14.8±1.2 kPa (p<0.0001) in PL. MitraClip decreased SLAD by 6.1±2.2 mm (p<0.0001) and increased Err in the sub-valvular lateral LV myocardium at ED by 0.09±0.04 (p<0.0001)). Furthermore, MitraClip in ↑LV_VOLUME was associated with persistent effects at ED but also at end-systole where peri-MitraClip leaflet stress was increased in AL by 31.9±14.4 kPa (p = 0.0268) and in PL by 22.5±23.7 kPa (p = 0.0101). Conclusions: MitraClip for FMR-CAD increases mitral leaflet stress and radial strain in LV sub-valvular myocardium. Mechanical effects of MitraClip are augmented by LV enlargement. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: PloS one, 2019 (prima pubblicazione 2019-10-10). Identificativi: PMID 31600276 · PMCID PMC6786765 · DOI 10.1371/journal.pone.0223472. Descrittori MeSH principali: Surgical Instruments; Finite Element Analysis; Models, Cardiovascular. Pagina: https://europepmc.org/article/MED/31600276 — https://doi.org/10.1371/journal.pone.0223472. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-11-10T09:46:27.231Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.