Metraipolis › archive › dc_88a36bde7761

Sensitivity Scaling and Limits of Cavity Enhancement in Miniaturized Optically Pumped Magnetometers — arXiv:2608.16670

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.16670
License (as archived)
CC0-1.0
Archived
2026-10-19T01:05:28.477Z
SHA-256 of the archived text
4249d0430cebc5002a82ae97be97faeb233afd5517ba79389f7ba4d2077d7d70
Stable URL of this page
https://metraipolis.com/documento/dc_88a36bde7761

How to cite

Sensitivity Scaling and Limits of Cavity Enhancement in Miniaturized Optically Pumped Magnetometers — arXiv:2608.16670 — arXiv (en), https://arxiv.org/abs/2608.16670 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_88a36bde7761 (Metraipolis archive dc_88a36bde7761, sha256 4249d0430cebc5002a82ae97be97faeb233afd5517ba79389f7ba4d2077d7d70)
BibTeX
@misc{dc88a36bde7761,
  title = {Sensitivity Scaling and Limits of Cavity Enhancement in Miniaturized Optically Pumped Magnetometers — arXiv:2608.16670},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.16670},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_88a36bde7761; sha256 4249d0430cebc5002a82ae97be97faeb233afd5517ba79389f7ba4d2077d7d70},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.16670. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The sensitivity of miniaturized optically pumped magnetometers (OPMs) is limited by weak atom-light coupling, which an optical cavity can enhance. In this work, we model the photon-shot-noise-limited sensitivity of cavity-enhanced OPMs in the regime of strongly collisionally broadened optical transitions, characteristic of buffer-gas-filled miniaturized vapor cells. The cavity enhancement is benchmarked against a single-pass free-induction-decay OPM employing Faraday-rotation readout, with the probe power and detuning jointly optimized using the Cramér-Rao lower bound as a figure of merit. For a Fabry-Pérot cavity, we compare side-of-fringe, homodyne, Pound-Drever-Hall, and Faraday-rotation readout. All four yield an optimal sensitivity enhancement scaling as $\alpha\sqrt{2\mathcal{F}/\pi}$, where $\mathcal{F}$ is the cavity finesse and $0.5\leq \alpha \leq 1$ is a readout-dependent prefactor. The enhancement is maximized at critical coupling, and we quantify its degradation away from this point. We further show that, despite spin-dependent absorption associated with the ensemble's vector polarizability, near-critical coupling can be maintained throughout spin precession at arbitrary finesse by exceeding a derived probe-power threshold and increasing the atomic detuning with finesse. We also establish a limit to the maximum cavity enhancement set by vector light-shift noise.

Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-08-18 in quant-ph).
Categorie arXiv: Atomic Physics (physics.atom-ph) ; Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2608.16670 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).