Metraipolis › archive › dc_886fae798d6f

DER-Fault: A Simulation-Based Fault Dataset for DER-Integrated Distribution Systems Under Diverse Operating Conditions — arXiv:2609.36247

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.36247
License (as archived)
CC0-1.0
Archived
2026-10-07T20:52:03.601Z
SHA-256 of the archived text
f9ea03736501b85b8f7e496a3ee4c44775d8d709efa5e219861c0ea36102a239
Stable URL of this page
https://metraipolis.com/documento/dc_886fae798d6f

How to cite

DER-Fault: A Simulation-Based Fault Dataset for DER-Integrated Distribution Systems Under Diverse Operating Conditions — arXiv:2609.36247 — arXiv (en), https://arxiv.org/abs/2609.36247 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_886fae798d6f (Metraipolis archive dc_886fae798d6f, sha256 f9ea03736501b85b8f7e496a3ee4c44775d8d709efa5e219861c0ea36102a239)
BibTeX
@misc{dc886fae798d6f,
  title = {DER-Fault: A Simulation-Based Fault Dataset for DER-Integrated Distribution Systems Under Diverse Operating Conditions — arXiv:2609.36247},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.36247},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_886fae798d6f; sha256 f9ea03736501b85b8f7e496a3ee4c44775d8d709efa5e219861c0ea36102a239},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.36247. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The growth of distributed energy resource (DER) integration introduces greater variability in distribution system operating conditions, creating a need for comprehensive datasets for developing and evaluating data-driven fault diagnostic methods. This paper presents \textbf{DER-Fault}, a simulation-based dataset generated in OpenDSS using the Iowa 240-bus distribution system with photovoltaic (PV) generation, electric vehicle (EV) charging, and vehicle-to-grid (V2G) operation. To capture annual load variability while maintaining a manageable number of simulation cases, 60 representative operating conditions are selected from 8,760 hourly load profiles, covering peak, off-peak, transition, typical weekday, and typical weekend conditions. Six DER scenarios with varying PV and EV penetration levels and V2G participation are considered. The dataset includes normal operation and ten short-circuit fault classes, with varying fault resistance. Pre- and post-fault voltage and line-current phasor measurements are recorded at selected measurement locations, resulting in 19,800 simulation cases. Technical validation demonstrates broad coverage of annual loading and DER operating conditions, distinct phase-specific responses corresponding to the simulated fault types, and a consistent reduction in voltage-phasor disturbance with increasing fault resistance. The resulting dataset provides a structured resource for developing and evaluating machine-learning and other data-driven methods for fault detection, classification, and localization in DER-integrated distribution systems.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-30 in eess.SP).
Categorie arXiv: Signal Processing (eess.SP).
Pagina del lavoro: https://arxiv.org/abs/2609.36247 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T20:14:59.967Z dalla pagina https://arxiv.org/catchup/eess.SP/2026-09-30?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).