Metraipolis › archive › dc_8756dbfc4017

AnesTRACE: Benchmarking Intraoperative Anesthesia from Multimodal Perception to Multi-step Decision-Making — arXiv:2609.32740

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.32740
License (as archived)
CC0-1.0
Archived
2026-10-07T23:51:03.445Z
SHA-256 of the archived text
59c83feaa578756ad09ae52368f864e22c53882be6ac9096503badfc3dd7d330
Stable URL of this page
https://metraipolis.com/documento/dc_8756dbfc4017

How to cite

AnesTRACE: Benchmarking Intraoperative Anesthesia from Multimodal Perception to Multi-step Decision-Making — arXiv:2609.32740 — arXiv (en), https://arxiv.org/abs/2609.32740 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_8756dbfc4017 (Metraipolis archive dc_8756dbfc4017, sha256 59c83feaa578756ad09ae52368f864e22c53882be6ac9096503badfc3dd7d330)
BibTeX
@misc{dc8756dbfc4017,
  title = {AnesTRACE: Benchmarking Intraoperative Anesthesia from Multimodal Perception to Multi-step Decision-Making — arXiv:2609.32740},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.32740},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_8756dbfc4017; sha256 59c83feaa578756ad09ae52368f864e22c53882be6ac9096503badfc3dd7d330},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.32740. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Intraoperative anesthesia requires systems to interpret evolving multimodal evidence, recommend timely management, and revise decisions as patient states change, yet existing benchmarks usually isolate perception or single-point reasoning. We introduce AnesTRACE, an evaluation suite comprising AnesTRACE-Bench and AnesTRACE-Eval. Built from public perioperative datasets with anesthesiologist annotation, AnesTRACE-Bench evaluates Intraoperative Perception, Single-point Anesthesia Decision-Making, and Multi-step Anesthesia Decision-Making. AnesTRACE-Eval assesses open-ended responses through anesthesiologist-defined criteria for Clinical Correctness, Evidence Grounding, Task Completeness, and Safety, with Temporal Consistency for multi-step decisions; its domain-specific evaluator is trained by supervised fine-tuning and preference alignment on expert-reviewed judgments. Across more than 30 models, fine-grained visual grounding and intervention selection remain difficult: the leading model reaches only 32.2 mIoU for TEE visual grounding and retains a 17.5\% Major/Critical Safety Error Rate in multi-step management. Evaluator alignment with anesthesiologists improves across both training stages, while the best decision quality is accompanied by a 74.3-second P95 Latency. These results show that aggregate performance alone does not establish safe, timely longitudinal decision-making. We release our code at this https URL .

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-29 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2609.32740 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T23:29:27.089Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).