Metraipolis › archive › dc_86a18c78a703

Enhanced-sensitivity optical sensing of magnetic fields using postselected amplification and continuous-wave power recycling — arXiv:2611.09379

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.09379
License (as archived)
CC0-1.0
Archived
2026-11-09T22:48:15.260Z
SHA-256 of the archived text
ea9a0a9be686067ab27b7fdea00c2ebd809ca11fe3258bc0899cfb56aa1247a1
Stable URL of this page
https://metraipolis.com/documento/dc_86a18c78a703

How to cite

Enhanced-sensitivity optical sensing of magnetic fields using postselected amplification and continuous-wave power recycling — arXiv:2611.09379 — arXiv (en), https://arxiv.org/abs/2611.09379 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_86a18c78a703 (Metraipolis archive dc_86a18c78a703, sha256 ea9a0a9be686067ab27b7fdea00c2ebd809ca11fe3258bc0899cfb56aa1247a1)
BibTeX
@misc{dc86a18c78a703,
  title = {Enhanced-sensitivity optical sensing of magnetic fields using postselected amplification and continuous-wave power recycling — arXiv:2611.09379},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.09379},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_86a18c78a703; sha256 ea9a0a9be686067ab27b7fdea00c2ebd809ca11fe3258bc0899cfb56aa1247a1},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.09379. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Given the importance of precision weak magnetic field measurement, and noting that postselected amplification has not yet been well applied in this area, in this work we propose to combine the technique of postselected amplification with continuous-wave power recycling for enhanced-sensitivity optical sensing of weak magnetic fields. Based on rigorous derivations, we obtain compact expressions for the total postselection probability and the signal-to-noise ratio. We also analyze the effects originating from various non-ideal factors. In contrast to pulse recycling, continuous-wave recycling has lower control requirements and is more experimentally feasible.

Tema degli esploratori: fisica e astronomia (elenco arXiv quant-ph, nuovi lavori del giorno).
Categorie arXiv: Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2611.09379 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-09T22:42:14.932Z dalla pagina https://arxiv.org/list/quant-ph/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).