Metraipolis › archive › dc_86014f34a9a7

Real-time Assessment of Distribution Grid Security through Adaptive Smart Meter Measurements — arXiv:2608.04253

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.04253
License (as archived)
CC0-1.0
Archived
2026-10-31T12:13:19.280Z
SHA-256 of the archived text
7fa1699752dc512d900ed4d852f14924966731eb73044f39fba317eb906f7a57
Stable URL of this page
https://metraipolis.com/documento/dc_86014f34a9a7

How to cite

Real-time Assessment of Distribution Grid Security through Adaptive Smart Meter Measurements — arXiv:2608.04253 — arXiv (en), https://arxiv.org/abs/2608.04253 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_86014f34a9a7 (Metraipolis archive dc_86014f34a9a7, sha256 7fa1699752dc512d900ed4d852f14924966731eb73044f39fba317eb906f7a57)
BibTeX
@misc{dc86014f34a9a7,
  title = {Real-time Assessment of Distribution Grid Security through Adaptive Smart Meter Measurements — arXiv:2608.04253},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.04253},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_86014f34a9a7; sha256 7fa1699752dc512d900ed4d852f14924966731eb73044f39fba317eb906f7a57},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.04253. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The rapid expansion of distributed energy resources is heightening uncertainty and variability in distribution system operations, potentially leading to power quality challenges such as voltage magnitude violations and excessive voltage unbalance. Ensuring the dependable and secure operation of distribution grids requires system real-time assessment. However, constraints in sensing, measurement, and communication capabilities within distribution grids result in limited awareness of the system's state. To achieve better real-time estimates of distribution system security, we propose a real-time security assessment based on data from smart meters, which are already prevalent in most distribution grids. Assuming that it is possible to obtain a limited number of voltage magnitude measurements in real time, we design an iterative algorithm to adaptively identify a subset of smart meters whose real-time measurements allow us to certify that all voltage magnitudes remain within bounds. This algorithm iterates between (1) solving optimization problems to determine the worst possible voltage magnitudes, given a limited set of voltage magnitude measurements, and (2) leveraging the solutions and sensitivity information from these problems to update the measurement set. Numerical tests on the IEEE 123 distribution feeder demonstrate that the proposed algorithm consistently identifies and tracks the nodes with the highest and lowest voltage magnitude, even as the load changes over time.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-08-06 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2608.04253 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-31T12:03:41.304Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-08-06?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).