Metraipolis › archive › dc_84bd13a7f558

One-Slide Calibration of Pathology Foundation Models — arXiv:2610.08944

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.08944
License (as archived)
CC0-1.0
Archived
2026-10-08T11:10:22.439Z
SHA-256 of the archived text
750f46708135ae14668ea3a6bbd1c83062c711f4fd5d1f6f1bf2c30acc57ee3f
Stable URL of this page
https://metraipolis.com/documento/dc_84bd13a7f558

How to cite

One-Slide Calibration of Pathology Foundation Models — arXiv:2610.08944 — arXiv (en), https://arxiv.org/abs/2610.08944 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_84bd13a7f558 (Metraipolis archive dc_84bd13a7f558, sha256 750f46708135ae14668ea3a6bbd1c83062c711f4fd5d1f6f1bf2c30acc57ee3f)
BibTeX
@misc{dc84bd13a7f558,
  title = {One-Slide Calibration of Pathology Foundation Models — arXiv:2610.08944},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.08944},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_84bd13a7f558; sha256 750f46708135ae14668ea3a6bbd1c83062c711f4fd5d1f6f1bf2c30acc57ee3f},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.08944. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Scanner variation changes how pathology foundation models represent the same tissue. We introduce SlideRuler, which uses regions within a slide as internal controls to estimate and correct acquisition-induced shifts in other regions. A transfer map learned from paired rescans enables calibration from a single scan at inference while keeping the foundation model fixed. Across two encoders and five SCORPION scanners, learned transfer reduces mean target-to-source embedding distance by 16.3-38.5% relative to raw embeddings. Comparisons with unrelated same-scanner controls reveal a positive same-slide contribution across all four evaluation settings, including scanner holdout. A source-anchored variant reduces source-feature displacement by 47.7-83.6% relative to learned transfer while retaining most of its alignment gain. By drawing calibration information from the slide itself, SlideRuler offers a path toward more consistent use of frozen pathology models across imaging systems.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2610.08944 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T10:14:06.030Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).