Metraipolis › archive › dc_84b02b990a68

Upper extremity prosthetic selection influences loading of transhumeral osseointegrated systems — Europe PMC PMID:32760149

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/32760149
DOI
10.1371/journal.pone.0237179
License (as archived)
CC0-1.0
Archived
2026-11-07T21:22:29.237Z
SHA-256 of the archived text
75dfdbc8fd62ab949a7e5248420c44b5d087f6b229390d528d33710f971cc867
Stable URL of this page
https://metraipolis.com/documento/dc_84b02b990a68

How to cite

Upper extremity prosthetic selection influences loading of transhumeral osseointegrated systems — Europe PMC PMID:32760149 — Europe PMC (en), https://europepmc.org/article/MED/32760149 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_84b02b990a68 (Metraipolis archive dc_84b02b990a68, sha256 75dfdbc8fd62ab949a7e5248420c44b5d087f6b229390d528d33710f971cc867)
BibTeX
@misc{dc84b02b990a68,
  title = {Upper extremity prosthetic selection influences loading of transhumeral osseointegrated systems — Europe PMC PMID:32760149},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/32760149},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_84b02b990a68; sha256 75dfdbc8fd62ab949a7e5248420c44b5d087f6b229390d528d33710f971cc867},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/32760149. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Percutaneous osseointegrated (OI) implants are increasingly viable as an alternative to socket suspension of prosthetic limbs. Upper extremity prostheses have also become more complex to better replicate hand and arm function and attempt to recreate pre-amputation functional levels. With more functionality comes heavier devices that put more stress on the bone-implant interface, which could be an issue for implant stability. This study quantified transhumeral loading at defined amputation levels using four simulated prosthetic limb-types: (1) body powered hook, (2) myoelectric hook, (3) myoelectric hand, and (4) advanced prosthetic limb. Computational models were constructed to replicate the weight distribution of each prosthesis type, then applied to motion capture data collected during Advanced Activities of Daily Living (AADLs). For activities that did not include a handheld weight, the body powered prosthesis bending moments were 13-33% (range of means for each activity across amputation levels) of the intact arm moments (reference 100%), torsional moments were 12-15%, and axial pullout forces were 30-40% of the intact case (p≤0.001). The myoelectric hook and hand bending moments were 60-99%, torsional moments were 44-97%, and axial pullout forces were 62-101% of the intact case. The advanced prosthesis bending moments were 177-201%, torsional moments were 164-326%, and axial pullout forces were 133-185% of the intact case (p≤0.001). The addition of a handheld weight for briefcase carry and jug lift activities reduced the overall impact of the prosthetic model itself, where the body powered forces and moments were much closer to those of the intact model, and more complex prostheses further increased forces and moments beyond the intact arm levels. These results reveal a ranked order in loading magnitude according to complexity of the prosthetic device, and highlight the importance of considering the patient's desired terminal device when planning post-operative percutaneous OI rehabilitation and training.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: PloS one, 2020 (prima pubblicazione 2020-08-06).
Identificativi: PMID 32760149 · PMCID PMC7410272 · DOI 10.1371/journal.pone.0237179.
Descrittori MeSH principali: Osseointegration; Weight-Bearing; Torsion, Mechanical.
Pagina: https://europepmc.org/article/MED/32760149 — https://doi.org/10.1371/journal.pone.0237179. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-11-07T21:18:40.300Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.