Metraipolis › archive › dc_837a74dc4c7b
SparseTokenGS: Gaussian-based Sparse-View CBCT Reconstruction via Reusable Token Pool — arXiv:2610.38360
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.38360
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-31T06:12:40.356Z
- SHA-256 of the archived text
7044abc92987199824e924bb2104bcbd750aa87e95234859b20a3fbad6fc9b23- Stable URL of this page
https://metraipolis.com/documento/dc_837a74dc4c7b
How to cite
SparseTokenGS: Gaussian-based Sparse-View CBCT Reconstruction via Reusable Token Pool — arXiv:2610.38360 — arXiv (en), https://arxiv.org/abs/2610.38360 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_837a74dc4c7b (Metraipolis archive dc_837a74dc4c7b, sha256 7044abc92987199824e924bb2104bcbd750aa87e95234859b20a3fbad6fc9b23)
BibTeX
@misc{dc837a74dc4c7b,
title = {SparseTokenGS: Gaussian-based Sparse-View CBCT Reconstruction via Reusable Token Pool — arXiv:2610.38360},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.38360},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_837a74dc4c7b; sha256 7044abc92987199824e924bb2104bcbd750aa87e95234859b20a3fbad6fc9b23},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.38360. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Sparse-view cone-beam computed tomography is widely used for fast, low-dose volumetric imaging and lesion localization in dentistry and image-guided interventions, but it introduces severe artifacts. Feed-forward Gaussian methods transfer the reconstruction cost to training and decode each coordinate from projection-aligned features and neighboring anchors. However, information from the whole scan is written only when the field is constructed and cannot be retrieved during coordinate decoding, leaving the volume inconsistent within the scan. This is a common limitation of such methods: once the field is fixed, decoding uses only local features and reconstruction quality drops substantially. We propose SparseTokenGS, a Gaussian-based method for sparse-view cone-beam computed tomography reconstruction via a reusable token pool. Anchor Token Fusion and Point-Token Attention query this shared pool at the anchors and at the query coordinates, respectively. The local Gaussian prior is retained, and the volume is reconstructed in one forward pass, without per-scan optimization or a projection-domain loss. On three public chest and dental datasets, SparseTokenGS achieves the highest reconstruction performance among the compared methods. On clinical dental scans, reconstruction from only six projections reaches 29.51 decibels in peak signal-to-noise ratio and a structural similarity of 0.842 against the full-view reference, and off-the-shelf tooth-and-pulp segmentation keeps these structures separable for root-canal localization. Experiments on volcanic rock and chicken show performance after same-object adaptation. A reusable token pool gives feed-forward reconstruction a mechanism that keeps scan-wide context available through decoding and can benefit future rapid clinical lesion localization and analysis. The code is available at: this https URL . Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2610.38360 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-31T06:07:08.652Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).