Metraipolis › archive › dc_835f619069bb
A conditional generative model for T2-weighted prostate MRI with downstream evaluation in clinically significant cancer classificatio — arXiv:2611.02197
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.02197
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T11:41:50.898Z
- SHA-256 of the archived text
313e7c937c51ff628801515b2ecbc3b66faa1d0b7479168d2dbb989be238edce- Stable URL of this page
https://metraipolis.com/documento/dc_835f619069bb
How to cite
A conditional generative model for T2-weighted prostate MRI with downstream evaluation in clinically significant cancer classificatio — arXiv:2611.02197 — arXiv (en), https://arxiv.org/abs/2611.02197 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_835f619069bb (Metraipolis archive dc_835f619069bb, sha256 313e7c937c51ff628801515b2ecbc3b66faa1d0b7479168d2dbb989be238edce)
BibTeX
@misc{dc835f619069bb,
title = {A conditional generative model for T2-weighted prostate MRI with downstream evaluation in clinically significant cancer classificatio — arXiv:2611.02197},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.02197},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_835f619069bb; sha256 313e7c937c51ff628801515b2ecbc3b66faa1d0b7479168d2dbb989be238edce},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.02197. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Scarce and unrepresentative training data limit the performance of prostate MRI prediction models. Synthetic T2-weighted (T2W) MRI may augment training data containing clinically significant prostate cancer (csPCa) and transition zone (TZ) lesions. In this retrospective, single-center, ethics-committee-approved study, we developed a conditional generative model for T2W prostate MRI extending MAISI-v2 with csPCa class, zonal, and lesion-mask-guided conditioning, incorporating a relative advantage weighted loss fine-tuned on 1,303 patients (1,654 lesions). Fidelity was assessed by incremental ablation, and downstream utility was evaluated with T2W-based csPCa classifiers across five simulated training-data scenarios, each testing 18 synthetic-data configurations. The proposed model reduced Fréchet inception distance (FID) from 13.28 (pretrained MAISI-v2) to $2.04 \pm 0.06$ internally (PI-CAI: $3.83 \pm 0.51$). Synthetic augmentation significantly increased AUC in all five scenarios (+0.027 to +0.088; adjusted $p = 0.016$--$0.043$), though cross-institutional augmentation of PI-CAI yielded a non-significant gain (+0.013; $p = 0.397$). Overall, our model improved T2W MRI fidelity, and synthetic images improved csPCa classification under simulated data constraints, although benefit did not transfer significantly across institutions. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2611.02197 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T11:06:37.543Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).