Metraipolis › archive › dc_832c26d10e1f

Characterization of a reversible thermally-actuated polymer-valve: A potential dynamic treatment for congenital diaphragmatic hernia — Europe PMC PMID:30589888

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/30589888
DOI
10.1371/journal.pone.0209855
License (as archived)
CC0-1.0
Archived
2026-10-07T15:15:34.132Z
SHA-256 of the archived text
e009a5e1864e5768f2f3b870b1d7baff8cd054efdfbd7cd876d32860af527575
Stable URL of this page
https://metraipolis.com/documento/dc_832c26d10e1f

How to cite

Characterization of a reversible thermally-actuated polymer-valve: A potential dynamic treatment for congenital diaphragmatic hernia — Europe PMC PMID:30589888 — Europe PMC (en), https://europepmc.org/article/MED/30589888 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_832c26d10e1f (Metraipolis archive dc_832c26d10e1f, sha256 e009a5e1864e5768f2f3b870b1d7baff8cd054efdfbd7cd876d32860af527575)
BibTeX
@misc{dc832c26d10e1f,
  title = {Characterization of a reversible thermally-actuated polymer-valve: A potential dynamic treatment for congenital diaphragmatic hernia — Europe PMC PMID:30589888},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/30589888},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_832c26d10e1f; sha256 e009a5e1864e5768f2f3b870b1d7baff8cd054efdfbd7cd876d32860af527575},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/30589888. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Background: Congenital diaphragmatic hernia (CDH) is a fetal defect comprising an incomplete diaphragm and the herniation of abdominal organs into the chest cavity that interfere with fetal pulmonary development. Though the most promising treatment for CDH is via interventional fetoscopic tracheal occlusion (TO) surgery in-utero, it has produced mixed results due to the static nature of the inserted occlusion. We hypothesize that a suitable noninvasively-actuatable, cyclic-release tracheal occlusion device can be developed to enable dynamic tracheal occlusion (dTO) implementation. Objective: To conduct an in-vitro proof-of-concept investigation of the construction of thermo-responsive polymer valves designed for targeted activation within a physiologically realizable temperature range as a first step towards potential development of a noninvasively-actuatable implantable device to facilitate dynamic tracheal occlusion (dTO) therapy. Methods: Six thermo-responsive polymer valves, with a critical solution temperature slightly higher than normal physiological body temperature of 37°C, were fabricated using a copolymer of n-isopropylacrylamide (NIPAM) and dimethylacrylamide (DMAA). Three of the valves underwent ethylene oxide (EtO) sterilization while the other three served as controls for EtO-processing compatibility testing. Thermal response actuation of the valves and their steady-state flow performances were evaluated using water and caprine amniotic fluid. Results: All six valves consisting of 0.3-mole fraction of DMAA were tested for thermal actuation of caprine amniotic fluid flow at temperatures ranging from 30-44°C. They all exhibited initiation of valve actuation opening at ~40°C with full completion at ~44°C. The overall average coefficient of variation (CV) for the day-to-day flow performance of the valves tested was less than 12%. Based on a Student t-test, there was no significant difference in the operational characteristics for the EtO processed versus the non-EtO processed valves tested. Conclusions: We successfully fabricated and demonstrated physiological realizable temperature range operation of thermo-responsive polymer valves in-vitro and their suitability for standard EtO sterilization processing, a prerequisite for future in-vivo surgical implantation testing.

Tema degli esploratori: finanziamenti e grant (ricerca Europe PMC «seed money», solo open access).
Pubblicazione: PloS one, 2018 (prima pubblicazione 2018-12-27).
Identificativi: PMID 30589888 · PMCID PMC6307748 · DOI 10.1371/journal.pone.0209855.
Descrittori MeSH principali: Polymers; Prostheses and Implants.
Pagina: https://europepmc.org/article/MED/30589888 — https://doi.org/10.1371/journal.pone.0209855. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0.
Letto il 2026-10-07T14:49:19.824Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.