Metraipolis › archive › dc_83196fc04a81

Report Supervision — arXiv:2608.27668

Source
arXiv (en)
Original
https://arxiv.org/abs/2608.27668
License (as archived)
CC0-1.0
Archived
2026-10-17T11:32:54.508Z
SHA-256 of the archived text
78d115547dc386d599ea3dd51e006394802aff546b0a797808c6c01e84a56819
Stable URL of this page
https://metraipolis.com/documento/dc_83196fc04a81

How to cite

Report Supervision — arXiv:2608.27668 — arXiv (en), https://arxiv.org/abs/2608.27668 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_83196fc04a81 (Metraipolis archive dc_83196fc04a81, sha256 78d115547dc386d599ea3dd51e006394802aff546b0a797808c6c01e84a56819)
BibTeX
@misc{dc83196fc04a81,
  title = {Report Supervision — arXiv:2608.27668},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2608.27668},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_83196fc04a81; sha256 78d115547dc386d599ea3dd51e006394802aff546b0a797808c6c01e84a56819},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.27668. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Segmentation models can surpass radiologists, classification models, and vision-language models in tumor detection. Importantly, segmentation models outline tumors, allowing radiologists to better verify and trust the AI output. Their main limitation is the scarcity of tumor masks: creating one 3D tumor mask takes up to 30 minutes, so most public CT datasets contain only a few hundred masks, and even the largest private datasets contain only a couple of thousand. Tumor masks are not produced in clinical routine, but radiology reports are. Public datasets contain tens of thousands of CT-Report pairs, and hospitals contain hundreds of thousands. These reports describe tumors in detail, providing large-scale, informative training data. Here, we introduce Report Supervision (R-Super), a training framework that uses reports to directly supervise and improve tumor segmentation. R-Super introduces new loss functions that teach segmentation models to segment tumors that match report descriptions of tumor count, sizes, and locations. Reports are only used for training. We evaluated R-Super on kidney and pancreatic tumor segmentation, exploring diverse training data sizes, up to 41,418 CT-Report plus 3,488 pancreatic tumor CT-Mask pairs. On external validation, R-Super increased tumor detection F1-Score and segmentation DSC by up to +15% with respect to mask-only training. It also surpassed alternative methods such as CLIP and multi-task learning. Leveraging numerous readily available reports to supplement scarce masks, R-Super strongly improves AI performance when very few training masks are available (e.g., 50), and when many masks are available (e.g., 3,488), unlocking scale in tumor segmentation.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-31 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2608.27668 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-17T11:10:05.261Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-08-31?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).