Metraipolis › archive › dc_80f9601d76b1
EviDent-CBCT: Evidence-Bottlenecked Report Generation from Dental CBCT under Non-Exhaustive Report Supervision — arXiv:2610.02375
- Source
- arXiv
- Original
- https://arxiv.org/abs/2610.02375
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-05T22:49:57.542Z
- SHA-256 of the archived text
af2e53a51e9cd172fbf92f8dc4959a0419fb1a9fb67ceae3f302420261dcf0c8- Stable URL of this page
https://metraipolis.com/documento/dc_80f9601d76b1
How to cite
EviDent-CBCT: Evidence-Bottlenecked Report Generation from Dental CBCT under Non-Exhaustive Report Supervision — arXiv:2610.02375 — arXiv, https://arxiv.org/abs/2610.02375 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_80f9601d76b1 (Metraipolis archive dc_80f9601d76b1, sha256 af2e53a51e9cd172fbf92f8dc4959a0419fb1a9fb67ceae3f302420261dcf0c8)
BibTeX
@misc{dc80f9601d76b1,
title = {EviDent-CBCT: Evidence-Bottlenecked Report Generation from Dental CBCT under Non-Exhaustive Report Supervision — arXiv:2610.02375},
howpublished = {arXiv},
url = {https://arxiv.org/abs/2610.02375},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_80f9601d76b1; sha256 af2e53a51e9cd172fbf92f8dc4959a0419fb1a9fb67ceae3f302420261dcf0c8},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv, https://arxiv.org/abs/2610.02375. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Dento-maxillofacial cone-beam CT (CBCT) reports may contain dozens of tooth-specific, anatomical, and spatial findings from a single 3D scan. Learning to generate such reports from limited clinical data is challenging because routine reports may not exhaustively document image findings, and a non-mention may reflect either absence or non-reporting. We present EviDent-CBCT, an evidence-bottlenecked framework designed for this incomplete supervision. An anatomy-aware network maps each CBCT scan to a discrete record of tooth-level, global, and tooth-IAC evidence. A dental-logic consistency projection reconciles incompatible evidence before a deterministic renderer and an image-blind local language model generate the report using only this record. For tooth-level evidence, reliability-aware training uses eligible non-mentions as reduced-weight negatives, while unreported global and tooth-IAC labels remain unknown. A metal-sensitive input channel preserves intensity cues from dental materials. Across three validation runs, EviDent-CBCT achieves $0.666\pm0.006$ merged evidence set-F1 and $0.402\pm0.003$ RadFact-Lite-Dental logical-F1, versus $0.371\pm0.018$ for the strongest controlled direct baseline. In the ODIN 2026 challenge, it ranked second in automated evaluation and third in blinded clinical Arena comparison on the hidden test set. These results support the discrete evidence record as an effective and auditable interface for CBCT report generation. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2610.02375 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-05T22:45:55.745Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).