Metraipolis › archive › dc_80cfd710e782
PhaseSync-Exo: Human Clock Anchored Reference Adaptation for Dynamic Gait Tracking — arXiv:2609.38824
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.38824
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T15:11:41.084Z
- SHA-256 of the archived text
0bde5612eb607b93a0d5419743cc0144a6542e933b3f609ee7cb270d9019ffba- Stable URL of this page
https://metraipolis.com/documento/dc_80cfd710e782
How to cite
PhaseSync-Exo: Human Clock Anchored Reference Adaptation for Dynamic Gait Tracking — arXiv:2609.38824 — arXiv (en), https://arxiv.org/abs/2609.38824 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_80cfd710e782 (Metraipolis archive dc_80cfd710e782, sha256 0bde5612eb607b93a0d5419743cc0144a6542e933b3f609ee7cb270d9019ffba)
BibTeX
@misc{dc80cfd710e782,
title = {PhaseSync-Exo: Human Clock Anchored Reference Adaptation for Dynamic Gait Tracking — arXiv:2609.38824},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.38824},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_80cfd710e782; sha256 0bde5612eb607b93a0d5419743cc0144a6542e933b3f609ee7cb270d9019ffba},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.38824. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Human-aware exoskeleton walking requires reconstructing gait, tracking diverse motions under dynamic constraints, and preserving human timing. We present PhaseSync-Exo, which combines two-IMU CNN-Transformer reconstruction, factorized amplitude-cadence retargeting with curriculum-trained recurrent control, and a human-clock-anchored adapter (HCA). HCA combines human-clock attraction with robot-relative feedback to adjust reference rate while preserving forward progression and continuity. The reconstruction module achieves a mean absolute error (MAE) of 3.24 degrees on a held-out recording, and the frozen tracking policy completes 356 of 357 amplitude-frequency trials. Two complementary dynamic comparisons isolate HCA's timing benefit without retraining. Against robot-relative correction, HCA reduces human-clock phase MAE from 95.55 degrees to 10.99 degrees, limiting reference drift. When human and delivered phases initially differ, it reduces phase MAE from 72.02 degrees to 13.90 degrees versus fixed-clock continuation. Compared with immediate phase reset, HCA reduces transient reference-tracking hip RMSE by 22.7% without reference jumps. All 420 timing rollouts complete without falls. These simulation results support continuous phase acquisition and sustained alignment to an independent human clock. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-10-01 in cs.RO). Categorie arXiv: Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2609.38824 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T14:44:47.377Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-10-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).