Metraipolis › archive › dc_807d9506ca5b
An Analysis of the Accuracy of the Added Length De-Embedding Methods for Coaxial to Waveguide Adapters in the X-Band — arXiv:2608.06313
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.06313
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-31T11:09:37.383Z
- SHA-256 of the archived text
9b92e63e1d0729bcb694e95c9955ae311adfb8567b2f4601d8ceb273668690ae- Stable URL of this page
https://metraipolis.com/documento/dc_807d9506ca5b
How to cite
An Analysis of the Accuracy of the Added Length De-Embedding Methods for Coaxial to Waveguide Adapters in the X-Band — arXiv:2608.06313 — arXiv (en), https://arxiv.org/abs/2608.06313 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_807d9506ca5b (Metraipolis archive dc_807d9506ca5b, sha256 9b92e63e1d0729bcb694e95c9955ae311adfb8567b2f4601d8ceb273668690ae)
BibTeX
@misc{dc807d9506ca5b,
title = {An Analysis of the Accuracy of the Added Length De-Embedding Methods for Coaxial to Waveguide Adapters in the X-Band — arXiv:2608.06313},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.06313},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_807d9506ca5b; sha256 9b92e63e1d0729bcb694e95c9955ae311adfb8567b2f4601d8ceb273668690ae},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.06313. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
This paper assesses the accuracy of the "added length method" (also known as port extension or channel offset) for de-embedding coaxial-to-waveguide transitions in the X-band, comparing it to full waveguide calibration on both Keysight and Rohde & Schwarz VNAs. The study examines the trade-offs between cost and measurement accuracy, highlighting the feasibility of using these mathematical correction techniques in the absence of dedicated waveguide calibration kits or full S-parameter characterizations of the transitions. The analysis concluded that when using coaxial-to-waveguide transitions the added length method produces accurate results for transmission measurements only. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-07 in eess.SP). Categorie arXiv: Signal Processing (eess.SP). Pagina del lavoro: https://arxiv.org/abs/2608.06313 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-31T10:59:50.832Z dalla pagina https://arxiv.org/catchup/eess.SP/2026-08-07?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).