Metraipolis › archive › dc_7f77d9deb9ce

Weak Values Beyond the Weak Limit: Measurement-Strength Invariance Under Post-Selection — arXiv:2609.22976

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.22976
License (as archived)
CC0-1.0
Archived
2026-10-09T22:46:35.102Z
SHA-256 of the archived text
90df01927f5bf527a27d522cfcecbdfa8f05ed71a25624708817281798c27c72
Stable URL of this page
https://metraipolis.com/documento/dc_7f77d9deb9ce

How to cite

Weak Values Beyond the Weak Limit: Measurement-Strength Invariance Under Post-Selection — arXiv:2609.22976 — arXiv (en), https://arxiv.org/abs/2609.22976 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_7f77d9deb9ce (Metraipolis archive dc_7f77d9deb9ce, sha256 90df01927f5bf527a27d522cfcecbdfa8f05ed71a25624708817281798c27c72)
BibTeX
@misc{dc7f77d9deb9ce,
  title = {Weak Values Beyond the Weak Limit: Measurement-Strength Invariance Under Post-Selection — arXiv:2609.22976},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.22976},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_7f77d9deb9ce; sha256 90df01927f5bf527a27d522cfcecbdfa8f05ed71a25624708817281798c27c72},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.22976. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Weak values are conventionally extracted in the limit of vanishing measurement strength. At finite strength, the corresponding post-selected conditional averages generally acquire nonlinear corrections and need not retain their weak value interpretation. Here we identify a class of measurement protocols for which this expectation fails: the conditional value reconstructed from the measuring probe is exactly independent of the probe strength and therefore coincides with the real part of the weak value. We first analyze this phenomenon in the measurement--disturbance protocol introduced by Lund and Wiseman. We then establish conditions under which this invariance persists, showing that it is determined by the interplay between the probe interaction, a subsequent measurement interaction with an ancillary apparatus, and the final post-selection. These results demonstrate that weak coupling, although generally sufficient for accessing weak values, is not always necessary.

Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-22 in quant-ph).
Categorie arXiv: Quantum Physics (quant-ph).
Pagina del lavoro: https://arxiv.org/abs/2609.22976 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-09T22:25:52.339Z dalla pagina https://arxiv.org/catchup/quant-ph/2026-09-22?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).