Metraipolis › archive › dc_7e83d0f8aa27
GCN-Based Model for Fault Classification in Distribution Networks under Harmonic Distortion — arXiv:2609.27169
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.27169
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-08T13:37:26.835Z
- SHA-256 of the archived text
95b2f93ceb92ea412157dc2649edd782266aab7c7e104b9a5eb00e51b833149e- Stable URL of this page
https://metraipolis.com/documento/dc_7e83d0f8aa27
How to cite
GCN-Based Model for Fault Classification in Distribution Networks under Harmonic Distortion — arXiv:2609.27169 — arXiv (en), https://arxiv.org/abs/2609.27169 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_7e83d0f8aa27 (Metraipolis archive dc_7e83d0f8aa27, sha256 95b2f93ceb92ea412157dc2649edd782266aab7c7e104b9a5eb00e51b833149e)
BibTeX
@misc{dc7e83d0f8aa27,
title = {GCN-Based Model for Fault Classification in Distribution Networks under Harmonic Distortion — arXiv:2609.27169},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.27169},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_7e83d0f8aa27; sha256 95b2f93ceb92ea412157dc2649edd782266aab7c7e104b9a5eb00e51b833149e},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.27169. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
The increasing integration of distributed energy resources introduces new challenges for accurate fault detection and classification in distribution networks. This paper presents a topology-aware graph convolutional network-based model for fault classification under inverter-induced harmonic distortion. The model uses pre-fault and post-fault voltage and current phasors, including harmonic components, mapped to the IEEE 34-bus system topology. The simulation data generated in OpenDSS encompass varying levels of penetration of solar photovoltaics (30%, 50%, 70%) and current total harmonic distortion (0%, 1%, 3%, 5%) across multiple fault types: single line-to-ground, line-to-line, double line-to-ground, and three-phase-to-ground. A differential evolution algorithm is employed to optimize the hyperparameters of the network, resulting in a three-layer model that achieves an F1-score of 0.98. Stress testing across scenarios confirms high robustness and minimal class confusion. The results demonstrate that a graph convolutional network-based model can effectively classify distribution faults under varying photovoltaic penetration levels and harmonically distorted conditions. Comparative analyses with convolutional neural network, long short-term memory, and multi-layer perceptron architectures demonstrate that the proposed model delivers superior classification performance, particularly under the most stressed condition with 70% photovoltaic penetration and 5% harmonic distortion. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-24 in eess.SP). Categorie arXiv: Signal Processing (eess.SP). Pagina del lavoro: https://arxiv.org/abs/2609.27169 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-08T13:16:32.381Z dalla pagina https://arxiv.org/catchup/eess.SP/2026-09-24?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).