Metraipolis › archive › dc_7e6924a2b08b
Reconstruction-Aware Cryo-EM Particle Picking — arXiv:2608.28838
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.28838
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T10:01:58.176Z
- SHA-256 of the archived text
d9b990272a3807008a99962af9c546bd3747b1022e2e11450251ee4e9575b649- Stable URL of this page
https://metraipolis.com/documento/dc_7e6924a2b08b
How to cite
Reconstruction-Aware Cryo-EM Particle Picking — arXiv:2608.28838 — arXiv (en), https://arxiv.org/abs/2608.28838 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_7e6924a2b08b (Metraipolis archive dc_7e6924a2b08b, sha256 d9b990272a3807008a99962af9c546bd3747b1022e2e11450251ee4e9575b649)
BibTeX
@misc{dc7e6924a2b08b,
title = {Reconstruction-Aware Cryo-EM Particle Picking — arXiv:2608.28838},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.28838},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_7e6924a2b08b; sha256 d9b990272a3807008a99962af9c546bd3747b1022e2e11450251ee4e9575b649},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.28838. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Cryo-electron microscopy (cryo-EM) determines the structures of proteins and macromolecular assemblies at near-atomic resolution, and the final 3D reconstruction depends on extracting a clean particle stack from noisy micrographs. This extraction decomposes into three sub-tasks, namely particle picking, contamination removal, and 2D class selection. Each of them, however, is trained and evaluated in isolation, and none is optimized for the reconstruction. We instead integrate the three sub-tasks into a single pipeline posed against downstream reconstruction quality. We instantiate the pipeline with a state-of-the-art component for each sub-task, CryoTransformer picking permissively, MicrographCleaner masking contamination, and CryoSift selecting 2D classes by a continuous quality score, and close the loop with a fine-tuning step that returns the surviving particles to the picker. The pipeline achieves a better 3D resolution than every picker we compare. We also show that the best 2D F1 is not the best resolution, so particle selection is better treated as one reconstruction-aware pipeline judged by the map it delivers. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-01 in cs.CV). Categorie arXiv: Biomolecules (q-bio.BM) ; Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2608.28838 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T09:28:48.252Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).