Metraipolis › archive › dc_7d5c158a2c69
Feature Space Guidance for Breast Cancer Classification in DCE-MRI — arXiv:2609.32555
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.32555
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-07T21:00:24.093Z
- SHA-256 of the archived text
0967c29fbba0a81e20425657af156de6aaf3e1d3bf6b41b6163b14a95c627a47- Stable URL of this page
https://metraipolis.com/documento/dc_7d5c158a2c69
How to cite
Feature Space Guidance for Breast Cancer Classification in DCE-MRI — arXiv:2609.32555 — arXiv (en), https://arxiv.org/abs/2609.32555 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_7d5c158a2c69 (Metraipolis archive dc_7d5c158a2c69, sha256 0967c29fbba0a81e20425657af156de6aaf3e1d3bf6b41b6163b14a95c627a47)
BibTeX
@misc{dc7d5c158a2c69,
title = {Feature Space Guidance for Breast Cancer Classification in DCE-MRI — arXiv:2609.32555},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.32555},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_7d5c158a2c69; sha256 0967c29fbba0a81e20425657af156de6aaf3e1d3bf6b41b6163b14a95c627a47},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.32555. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Dynamic contrast enhanced breast MRI (DCE-MRI) is a powerful clinical tool for breast cancer detection, providing high resolution anatomical detail together with rich temporal contrast information. However, high dimensional 4D inputs, small lesions, and heterogeneous acquisition protocols across clinical sites hinder robust automated classification of healthy, benign, and malignant cases. To address these challenges, we propose a framework that dynamically analyzes latent representations to adapt to protocol-specific characteristics. Spatial variability is mitigated by reducing confounding background uptake and compensating for misalignment caused by deformable soft tissue. Additionally, relationships in the latent space across phases are leveraged to select the most informative temporal features, improving robustness to protocol-specific temporal variability. Finally, task specific discriminative features are promoted through large scale supervised lesion segmentation pretraining, which substantially enhances downstream finetuning. Evaluated under leave-one-center-out validation on the ODELIA dataset and the held-out AMBL cohort, the proposed framework substantially outperforms finetuned radiology foundation models and prior methods, improving mean AUROC by nearly 8 points and balanced accuracy by 4 points over the strongest baseline. Additionally, our method achieved first place in the MICCAI ODELIA Breast MRI Challenge 2025, further demonstrating its effectiveness for robust breast cancer classification. We publicly release our codebase under this https URL . Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-09-29 in cs.AI). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2609.32555 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-07T20:29:02.387Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-09-29?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).