Metraipolis › archive › dc_7c92593d8a22
Cross-Spectral Dense Correspondence for Multimodal Spectral Medical Imaging — arXiv:2608.28341
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.28341
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-17T10:48:16.176Z
- SHA-256 of the archived text
e3ae5ba9efc7419581d305701b5f014326c05e9bc8bf89594d1c4dcfeb6c2d1f- Stable URL of this page
https://metraipolis.com/documento/dc_7c92593d8a22
How to cite
Cross-Spectral Dense Correspondence for Multimodal Spectral Medical Imaging — arXiv:2608.28341 — arXiv (en), https://arxiv.org/abs/2608.28341 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_7c92593d8a22 (Metraipolis archive dc_7c92593d8a22, sha256 e3ae5ba9efc7419581d305701b5f014326c05e9bc8bf89594d1c4dcfeb6c2d1f)
BibTeX
@misc{dc7c92593d8a22,
title = {Cross-Spectral Dense Correspondence for Multimodal Spectral Medical Imaging — arXiv:2608.28341},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.28341},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_7c92593d8a22; sha256 e3ae5ba9efc7419581d305701b5f014326c05e9bc8bf89594d1c4dcfeb6c2d1f},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.28341. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Precise dense correspondence is a fundamental prerequisite for multimodal spectral imaging systems that fuse disparate wavelength ranges for subsequent analysis in medical and scientific imaging. Corresponding image points are often observed with non-overlapping spectral sensitivities, leading to wavelength-dependent contrast changes, intensity inversions, and appearance shifts for which dense ground truth is difficult to obtain and conventional RGB-based training data provides only limited supervision. We address this data gap by introducing a sensor-agnostic cross-spectral modulation protocol on established correspondence benchmarks with intensity input projection, and by proposing a synthetic cross-spectral correspondence benchmark simulating physically plausible radiometric differences. Evaluation on several modern dense correspondence backbones trained with our unified cross-spectral protocol showed substantial improvements under severe spectral mismatch while maintaining performance on standard RGB benchmarks. Ablation experiments show that view-dependent channel selection and nonlinear radiometric transformations provide complementary robustness, indicating that the primary limitation of existing models is not their structural matching capacity but the mismatch between training distribution and spectral characteristics of the target image pair. Qualitative evaluations on heterogeneous medical spectral acquisition systems demonstrate the practical relevance of the proposed training data augmentation protocol as an enabler for spatially coherent spectral fusion in HSI workflows. Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-31 in cs.AI). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI). Pagina del lavoro: https://arxiv.org/abs/2608.28341 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-17T10:33:42.522Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-08-31?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).