Metraipolis › archive › dc_7bcd205176c6

Risk Assessment of Fair Multi-Period Dynamic Operating Envelopes under Uncertainty — arXiv:2610.42014

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.42014
License (as archived)
CC0-1.0
Archived
2026-11-02T08:13:55.815Z
SHA-256 of the archived text
1952f09470375bcba7e509775f871d811a927f9705e316de0c1b1e320e417839
Stable URL of this page
https://metraipolis.com/documento/dc_7bcd205176c6

How to cite

Risk Assessment of Fair Multi-Period Dynamic Operating Envelopes under Uncertainty — arXiv:2610.42014 — arXiv (en), https://arxiv.org/abs/2610.42014 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_7bcd205176c6 (Metraipolis archive dc_7bcd205176c6, sha256 1952f09470375bcba7e509775f871d811a927f9705e316de0c1b1e320e417839)
BibTeX
@misc{dc7bcd205176c6,
  title = {Risk Assessment of Fair Multi-Period Dynamic Operating Envelopes under Uncertainty — arXiv:2610.42014},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.42014},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_7bcd205176c6; sha256 1952f09470375bcba7e509775f871d811a927f9705e316de0c1b1e320e417839},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.42014. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Dynamic operating envelopes (DOEs) can allocate time-varying export capacity to distributed energy resources (DERs), and while they are not intended to make operations immune to voltage violations, they should guide operations to mostly remain inside expected values under changing regimes and residual forecast errors. However, although recent literature proposed many different techniques for implementing DOEs, there is sparse discussion of analyzing and quantifying the risk of using more or less conservative DOEs under uncertain operating regimes. Having this gap in mind, this paper develops a risk-oriented extension of a previously established fair distributed multi-period optimal power flow (OPF) framework, where fair or technical DOEs are fixed as first-stage decisions and the OPF leverages battery energy storage and renewable curtailment as recourse under regime uncertainties. An independent nonlinear AC power flow then computes a resulting ensemble, which is summarized by (i) voltage-violation probability, severity, and a persistence metric for consecutive out-of-band hours, (ii) curtailment and Jain and Gini indices, and (iii) model deviations. Different probability situations are assessed, ranging from uniform, sunny-heavy, night-peak-heavy, and adversarial, which separate the envelope design from the assumed operating distribution. An optional outer loop allows for fine-tuning a fairness--efficiency parameter under explicit violation and persistence budgets. The combination of the outer loop and the overall framework, which quantifies how often and how severely operating limits are exceeded, creates an auditable methodology mixing equitable export allocation, distributed recourse, and AC risk assessment for active distribution network operators, and this framework is assessed using up to 1000 Monte Carlo scenarios per mixture and DOE design.

Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno).
Categorie arXiv: Systems and Control (eess.SY) ; Computational Engineering, Finance, and Science (cs.CE).
Pagina del lavoro: https://arxiv.org/abs/2610.42014 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-02T07:52:46.317Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).