Metraipolis › archive › dc_7b4668603299
Stochastic Distribution Network Reconfiguration under Load Uncertainty — arXiv:2610.12154
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.12154
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-09T07:13:40.094Z
- SHA-256 of the archived text
7b93e6deaa25f2632b6acc999cbcb66b54dd4d7ba6d7862e763259b2f08a4c87- Stable URL of this page
https://metraipolis.com/documento/dc_7b4668603299
How to cite
Stochastic Distribution Network Reconfiguration under Load Uncertainty — arXiv:2610.12154 — arXiv (en), https://arxiv.org/abs/2610.12154 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_7b4668603299 (Metraipolis archive dc_7b4668603299, sha256 7b93e6deaa25f2632b6acc999cbcb66b54dd4d7ba6d7862e763259b2f08a4c87)
BibTeX
@misc{dc7b4668603299,
title = {Stochastic Distribution Network Reconfiguration under Load Uncertainty — arXiv:2610.12154},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.12154},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_7b4668603299; sha256 7b93e6deaa25f2632b6acc999cbcb66b54dd4d7ba6d7862e763259b2f08a4c87},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.12154. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
This paper investigates distribution network reconfiguration under demand uncertainty using a two-stage stochastic formulation. The network topology is selected in the first stage, whereas the electrical variables are determined separately for each scenario. The deterministic equivalent is formulated as a MISOCP problem that accounts for power balances, losses, voltage constraints, and radiality. Experiments on 12 networks, ranging from 17 to 10,561 nodes, consider three demand scenarios. Reconfiguration reduced expected losses in all instances, with reductions ranging from 3.23% to 65.23% and averaging 31.76%, while also reducing the number of voltage violations in the ex post evaluation by approximately 55%. Eleven of the 12 problems were solved to optimality within the prescribed time limit. However, the additional benefit of stochastic modeling was negligible because of the homothetic structure of the scenarios considered, which preserves the spatial distribution of loads. The results show that spatially heterogeneous scenarios are important for the representation of uncertainty to meaningfully affect reconfiguration decisions. Tema degli esploratori: calcolo e infrastrutture (elenco arXiv eess.SY, nuovi lavori del giorno). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2610.12154 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T07:07:42.938Z dalla pagina https://arxiv.org/list/eess.SY/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).