Metraipolis › archive › dc_7a5105f78f2b

Identity-Duplication Auditing in National-Scale Neuroimaging Repositories — arXiv:2610.09614

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.09614
License (as archived)
CC0-1.0
Archived
2026-10-08T12:47:27.886Z
SHA-256 of the archived text
f9a648912a5185c45e9e9f140a8e6cfd42cd240c9242bab4b545d9afd90fcfd5
Stable URL of this page
https://metraipolis.com/documento/dc_7a5105f78f2b

How to cite

Identity-Duplication Auditing in National-Scale Neuroimaging Repositories — arXiv:2610.09614 — arXiv (en), https://arxiv.org/abs/2610.09614 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_7a5105f78f2b (Metraipolis archive dc_7a5105f78f2b, sha256 f9a648912a5185c45e9e9f140a8e6cfd42cd240c9242bab4b545d9afd90fcfd5)
BibTeX
@misc{dc7a5105f78f2b,
  title = {Identity-Duplication Auditing in National-Scale Neuroimaging Repositories — arXiv:2610.09614},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.09614},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_7a5105f78f2b; sha256 f9a648912a5185c45e9e9f140a8e6cfd42cd240c9242bab4b545d9afd90fcfd5},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.09614. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

National-scale magnetic resonance imaging (MRI) repositories increasingly integrate data from different studies and institutions. However, subject identifiers that are valid only within individual datasets are no longer guaranteed to remain globally unique after aggregation, making it possible for the same subject to be assigned multiple identifiers, which we define as identity duplication. Such duplication can create leakage between training and test data and inflate apparent performance in downstream biomedical studies. Existing methods do not provide an end-to-end, image-based workflow for auditing this problem at repository scale. In this work, we present HAPPEN, a human-in-the-loop pipeline for auditing identity duplication in T1-weighted brain MRI repositories. It combines SHA-256 fingerprinting for exact-duplicate detection with supervised contrastive retrieval of non-identical scans that may originate from the same person. Retrieved pairs are reviewed as candidates in a locally hosted interface rather than automatically classified as duplicates. We deployed the workflow in a 95,129-scan aggregated repository and assessed end-to-end recovery using 54 genetic-reference pairs. Transferability was assessed by locally deploying the same workflow on 22,386 scans at an independent institution without model retraining or image transfer. Deployment in the study repository identified 1,316 exact-duplicate scan groups and 1,275 reviewer-supported near-duplicate subject groups. Of these groups, 56% and 82%, respectively, crossed dataset boundaries. All 54 genetic-reference pairs were recovered. The external team independently completed the full workflow using a locally selected operating threshold and review standard.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV).
Pagina del lavoro: https://arxiv.org/abs/2610.09614 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-08T12:18:15.392Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).