Metraipolis › archive › dc_799c2ac91e2c
Quantum noise and torque correlations in a torsion-bar Sagnac speed meter — arXiv:2610.19938
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.19938
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T14:52:09.223Z
- SHA-256 of the archived text
502890fec64e38384122dbd7231b8dabcb1154d759657688d278a430f6e4858c- Stable URL of this page
https://metraipolis.com/documento/dc_799c2ac91e2c
How to cite
Quantum noise and torque correlations in a torsion-bar Sagnac speed meter — arXiv:2610.19938 — arXiv (en), https://arxiv.org/abs/2610.19938 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_799c2ac91e2c (Metraipolis archive dc_799c2ac91e2c, sha256 502890fec64e38384122dbd7231b8dabcb1154d759657688d278a430f6e4858c)
BibTeX
@misc{dc799c2ac91e2c,
title = {Quantum noise and torque correlations in a torsion-bar Sagnac speed meter — arXiv:2610.19938},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.19938},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_799c2ac91e2c; sha256 502890fec64e38384122dbd7231b8dabcb1154d759657688d278a430f6e4858c},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.19938. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Quantum fluctuations entering through weakly transmitting mirrors can limit a torsion-bar Sagnac speed meter for low-frequency gravitational-wave detection, even when its optical layout suppresses radiation-pressure back action. We show that, in the Cryogenic sub-Hz cROss torsion bar detector with quantum NOn-demolition Speed meter (CHRONOS), vacuum fields entering from behind the end and middle test masses can dominate the low-frequency quantum noise despite cancellation of the torques on opposite ends of each bar. For a reference configuration with mirror power transmissions of only $10^{-7}$, these fields contribute $89.7\%$ of the total quantum-noise power spectral density at 0.1 Hz. Omitting them would underestimate the amplitude spectral density by a factor of 3.11. Our input-output model connects the correlations produced by successive optical interactions to the forces on each bar and the measured signal. This connection shows why strong torque cancellation does not, by itself, ensure a corresponding improvement in detector sensitivity. Replacing mirror transmission with absorption at fixed reflectivity leaves the excess quantum noise essentially unchanged for the two operating points studied. The predicted signal response and quantum noise agree with independent FINESSE 3 calculations as recycling detuning and homodyne angle are varied. These results establish rear vacuum fields as a limiting noise source in this torsion-bar speed meter and provide quantitative requirements for its mirror and readout design.
Tema degli esploratori: fisica e astronomia (elenco arXiv astro-ph.IM, nuovi lavori del giorno).
Categorie arXiv: General Relativity and Quantum Cosmology (gr-qc) ; Instrumentation and Methods for Astrophysics (astro-ph.IM).
Pagina del lavoro: https://arxiv.org/abs/2610.19938 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T14:03:53.637Z dalla pagina https://arxiv.org/list/astro-ph.IM/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).