Metraipolis › archive › dc_777b65af8dcd

Whole-Body Elasto-Geometrical Calibration of Wheeled Humanoid Robots Using a Shared-Waist Dual-Chain Model — arXiv:2611.07560

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.07560
License (as archived)
CC0-1.0
Archived
2026-11-06T14:54:01.220Z
SHA-256 of the archived text
9964f81019337dd0dc46948b66c5fc0248e836f632f12bdc32d6bbb9d70c48f1
Stable URL of this page
https://metraipolis.com/documento/dc_777b65af8dcd

How to cite

Whole-Body Elasto-Geometrical Calibration of Wheeled Humanoid Robots Using a Shared-Waist Dual-Chain Model — arXiv:2611.07560 — arXiv (en), https://arxiv.org/abs/2611.07560 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_777b65af8dcd (Metraipolis archive dc_777b65af8dcd, sha256 9964f81019337dd0dc46948b66c5fc0248e836f632f12bdc32d6bbb9d70c48f1)
BibTeX
@misc{dc777b65af8dcd,
  title = {Whole-Body Elasto-Geometrical Calibration of Wheeled Humanoid Robots Using a Shared-Waist Dual-Chain Model — arXiv:2611.07560},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.07560},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_777b65af8dcd; sha256 9964f81019337dd0dc46948b66c5fc0248e836f632f12bdc32d6bbb9d70c48f1},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.07560. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Wheeled humanoid robots carry both arms on one actuated waist, usually without torque sensors, so the accuracy of both end-effectors depends on a single waist model. After a first stage that estimates the tracker and target extrinsics, we identify the waist and both arms in one problem from the target positions on both flanges, measured by an optical tracker. The kinematic model is complete, with waist-base, parallel-axis, and branch parameters; arm compliances are driven by measured torques and waist compliances by gravity torques of the robot's mass model; and Gaussian priors with evidence-maximizing scales stabilize the estimate. Independent and sequential single-chain calibration are restrictions of this problem, and its waist information is the sum of the single-chain Schur complements. On two robots with different waists, each without and with a payload, calibration reduces the mean errors on held-out poses from 11.3-31.1 mm to 0.50-1.11 mm. For every training-set size from 20 poses to all, the method has 17-63% lower mean errors than adaptations of two published whole-body calibration methods, mainly through the waist compliance. Independent calibration yields two waist models; using either for both arms raises the other arm's error to up to 3.21 mm.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.RO, nuovi lavori del giorno).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2611.07560 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-06T14:25:57.563Z dalla pagina https://arxiv.org/list/cs.RO/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).