Metraipolis › archive › dc_7724d1edfee4

Design and Validation of an Antagonistic Tendon-Driven Dexterous Robotic Hand with Bidirectional Operation — arXiv:2609.36241

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.36241
License (as archived)
CC0-1.0
Archived
2026-10-07T19:15:07.762Z
SHA-256 of the archived text
d6685e2048e1c5f5fa29acc9d4129ab004aa3f99d6ab55f9cfbbd5d0489cd164
Stable URL of this page
https://metraipolis.com/documento/dc_7724d1edfee4

How to cite

Design and Validation of an Antagonistic Tendon-Driven Dexterous Robotic Hand with Bidirectional Operation — arXiv:2609.36241 — arXiv (en), https://arxiv.org/abs/2609.36241 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_7724d1edfee4 (Metraipolis archive dc_7724d1edfee4, sha256 d6685e2048e1c5f5fa29acc9d4129ab004aa3f99d6ab55f9cfbbd5d0489cd164)
BibTeX
@misc{dc7724d1edfee4,
  title = {Design and Validation of an Antagonistic Tendon-Driven Dexterous Robotic Hand with Bidirectional Operation — arXiv:2609.36241},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.36241},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_7724d1edfee4; sha256 d6685e2048e1c5f5fa29acc9d4129ab004aa3f99d6ab55f9cfbbd5d0489cd164},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.36241. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Dexterous robotic hands typically reproduce human hand morphology but inherit its one-sided grasping workspace, requiring wrist or arm reorientation to grasp from the opposite side. Existing reversible hands generally rely on non-anthropomorphic, soft, or task-specific finger arrangements, whereas conventional five-digit anthropomorphic hands remain designed primarily for palmar-side grasping. This paper presents an anthropomorphic, human-scale (200 mm length), lightweight (220 g), 3D-printed, 17-DoF robotic hand built on a bidirectional antagonistic tendon-routing mechanism, in which flexion/extension (except the coupled joint) and abduction/adduction at joints are actively driven without passive return springs. The proposed routing mechanism allows all degrees of freedom to cross their neutral configuration and form grasp closures on either the palmar or dorsal side. Experimental evaluation demonstrates an average motor-to-joint transmission error of 3.0%, an average joint transmission bandwidth of 13.2 Hz, a maximum fingertip force of 29 N, and a positioning repeatability up to 0.15 mm. The hand further achieves a Kapandji score of 8, successfully performs all 33 GRASP Taxonomy grasp types, and performs palmar- and dorsal-side grasping tasks, validating bidirectional operation in a compact, human-scale platform.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-30 in cs.RO).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2609.36241 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T18:40:59.390Z dalla pagina https://arxiv.org/catchup/cs.RO/2026-09-30?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).