Metraipolis › archive › dc_76d13c2190d0
Technical Preparations for the First Carbon-Ion Therapy Facility in the United States — arXiv:2610.10824
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.10824
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-09T06:39:35.953Z
- SHA-256 of the archived text
26409e7474b7a4b1c40e847f664e844b24858e40df6dbb2ef491667a429da658- Stable URL of this page
https://metraipolis.com/documento/dc_76d13c2190d0
How to cite
Technical Preparations for the First Carbon-Ion Therapy Facility in the United States — arXiv:2610.10824 — arXiv (en), https://arxiv.org/abs/2610.10824 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_76d13c2190d0 (Metraipolis archive dc_76d13c2190d0, sha256 26409e7474b7a4b1c40e847f664e844b24858e40df6dbb2ef491667a429da658)
BibTeX
@misc{dc76d13c2190d0,
title = {Technical Preparations for the First Carbon-Ion Therapy Facility in the United States — arXiv:2610.10824},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.10824},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_76d13c2190d0; sha256 26409e7474b7a4b1c40e847f664e844b24858e40df6dbb2ef491667a429da658},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.10824. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Carbon ion radiotherapy (CIRT) provides greater biological effectiveness than conventional photon therapy because of its high linear energy transfer and its ability to induce complex DNA damage. Mayo Clinic Florida is developing the first CIRT facility in the United States, using a synchrotron-based system with dose-driven continuous scanning (DDCS). Although DDCS improves delivery efficiency by keeping the beam on during spot transitions, it also creates the challenge of accurately modeling the dose delivered during beam motion (move dose), which is not fully addressed in current treatment planning systems. In this work, we present a method for accurate simulation of move dose to support Monte Carlo (MC) dose calculations. The method models realistic beam trajectories, including the characteristic hockey stick motion caused by different scanning speeds in the X and Y directions, and accounts for time-dependent beam intensity with linear ramp-up behavior. The beam path is divided into small segments, each represented by a move source with analytically determined position, intensity, and monitor units. Beam intensity fluctuations are also included using a stochastic model based on measurements. Validation using TOPAS simulations for a 430 MeV/u carbon ion beam in a water phantom showed accurate modeling of move dose and the resulting dose distributions. This method provides a practical framework for MC-based dose calculation in clinical CIRT. Tema degli esploratori: fisica e astronomia (elenco arXiv physics.comp-ph, nuovi lavori del giorno). Categorie arXiv: Medical Physics (physics.med-ph) ; Computational Physics (physics.comp-ph). Pagina del lavoro: https://arxiv.org/abs/2610.10824 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-09T05:59:31.399Z dalla pagina https://arxiv.org/list/physics.comp-ph/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).