Metraipolis › archive › dc_76ccf1326c5f
Molecular Communication for Plaque Sensing in a Vascular Bifurcation with Receiver Constraints — arXiv:2611.02773
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.02773
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-03T11:46:39.469Z
- SHA-256 of the archived text
dead9fdd0468687347fd8d99e1b308df93ae4087cae393d8a944a3222d81bafb- Stable URL of this page
https://metraipolis.com/documento/dc_76ccf1326c5f
How to cite
Molecular Communication for Plaque Sensing in a Vascular Bifurcation with Receiver Constraints — arXiv:2611.02773 — arXiv (en), https://arxiv.org/abs/2611.02773 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_76ccf1326c5f (Metraipolis archive dc_76ccf1326c5f, sha256 dead9fdd0468687347fd8d99e1b308df93ae4087cae393d8a944a3222d81bafb)
BibTeX
@misc{dc76ccf1326c5f,
title = {Molecular Communication for Plaque Sensing in a Vascular Bifurcation with Receiver Constraints — arXiv:2611.02773},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.02773},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_76ccf1326c5f; sha256 dead9fdd0468687347fd8d99e1b308df93ae4087cae393d8a944a3222d81bafb},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.02773. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Future molecular communication (MC) networks are envisioned to use the human cardiovascular system as a channel. Disease-related changes affect particle transport, allowing an MC receiver to also act as a sensor. In this work, we investigate plaque formation in a carotid bifurcation through a systematic fluid-dynamics simulation study with non-Newtonian blood rheology. We analyze how plaque geometry changes branch-specific particle reception and timing, and use these observations to estimate plaque-induced channel obstruction. At an illustrative reference of only 128 emitted particles, a 250 ms observation window and 50 ms temporal resolution, a Ridge detector estimates maximum local channel-width reduction with a mean absolute error of 8.30 percentage points. We evaluate robustness across system constraints like particle budgets, observation windows, branch access, detection efficiency, count resolution, and synchronization. Coarse counting has little effect when timing features remain available, whereas limited temporal resolution and clock uncertainty substantially affect short-window estimates. Extending the observation window to 1 s reduces these timing-related penalties. The results establish a baseline for plaque sensing from constrained MC observations and identify receiver capabilities relevant to the Internet of Bio-Nano Things. Tema degli esploratori: calcolo e infrastrutture (elenco arXiv cs.ET, nuovi lavori del giorno). Categorie arXiv: Emerging Technologies (cs.ET). Pagina del lavoro: https://arxiv.org/abs/2611.02773 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-03T11:09:07.277Z dalla pagina https://arxiv.org/list/cs.ET/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).