Metraipolis › archive › dc_76a7d9ce1810

EFormer: Temporally Aligned Local Correction for Continuous sEMG-Based Hand Pose Tracking — arXiv:2609.38932

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.38932
License (as archived)
CC0-1.0
Archived
2026-10-07T13:44:36.264Z
SHA-256 of the archived text
3ff557bf83d70f9e7ec5e569bd76c32268accc656f866116b4a356f00c41ae5a
Stable URL of this page
https://metraipolis.com/documento/dc_76a7d9ce1810

How to cite

EFormer: Temporally Aligned Local Correction for Continuous sEMG-Based Hand Pose Tracking — arXiv:2609.38932 — arXiv (en), https://arxiv.org/abs/2609.38932 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_76a7d9ce1810 (Metraipolis archive dc_76a7d9ce1810, sha256 3ff557bf83d70f9e7ec5e569bd76c32268accc656f866116b4a356f00c41ae5a)
BibTeX
@misc{dc76a7d9ce1810,
  title = {EFormer: Temporally Aligned Local Correction for Continuous sEMG-Based Hand Pose Tracking — arXiv:2609.38932},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.38932},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_76a7d9ce1810; sha256 3ff557bf83d70f9e7ec5e569bd76c32268accc656f866116b4a356f00c41ae5a},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.38932. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Surface electromyography (sEMG) provides a wearable, camera-free signal for continuous hand-motion inference. Mapping muscle activity to joint kinematics remains challenging because the recorded waveforms are indirect measurements, their relationship with motion changes over time, and individual anatomy and sensor placement alter the signal distribution. This paper presents EFormer, a residual feature-correction network built on a frozen tracking backbone. EFormer combines a high-rate event branch, temporally aligned local cross-attention, two causal rotary position embedding (RoPE) temporal layers, and a bounded, dynamically gated residual. EFormer receives 16-channel sEMG sampled at 2 kHz and fuses a 64-channel tracking representation at 25 Hz with a 128-channel event representation at 200 Hz. Cross-attention uses a nominal delay of 100 ms, a 300 ms history parameter, and a 50 ms tolerance; its causal mask restricts each query to events occurring 50-400 ms earlier. The correction scale is 0.15. The evaluated continuation-training configuration contains 585,376 trainable parameters and 5,974,508 frozen parameters. On the test set, EFormer achieves an MAE of 0.1546634 rad, an RMSE of 0.24063 rad, and an R^2 of 0.74801, compared with 0.1745326 rad, 0.2715448 rad, and 0.6791103 for the official tracking baseline. EFormer reduces MAE by 11.38% relative to the baseline. The results show that temporally aligned event-feature correction can reduce continuous hand-pose tracking error.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-10-01 in cs.HC).
Categorie arXiv: Machine Learning (cs.LG) ; Human-Computer Interaction (cs.HC).
Pagina del lavoro: https://arxiv.org/abs/2609.38932 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T13:17:28.271Z dalla pagina https://arxiv.org/catchup/cs.HC/2026-10-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).