Metraipolis › archive › dc_75c758247751

iMED: A Multi-Endoscope Dataset for Surgical 3D Perception — arXiv:2611.04755

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.04755
License (as archived)
CC0-1.0
Archived
2026-11-04T19:03:26.955Z
SHA-256 of the archived text
7fc630188228e85ef8fafb340f60269047f23ac1b401d3b2cfd525c9017a31ca
Stable URL of this page
https://metraipolis.com/documento/dc_75c758247751

How to cite

iMED: A Multi-Endoscope Dataset for Surgical 3D Perception — arXiv:2611.04755 — arXiv (en), https://arxiv.org/abs/2611.04755 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_75c758247751 (Metraipolis archive dc_75c758247751, sha256 7fc630188228e85ef8fafb340f60269047f23ac1b401d3b2cfd525c9017a31ca)
BibTeX
@misc{dc75c758247751,
  title = {iMED: A Multi-Endoscope Dataset for Surgical 3D Perception — arXiv:2611.04755},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.04755},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_75c758247751; sha256 7fc630188228e85ef8fafb340f60269047f23ac1b401d3b2cfd525c9017a31ca},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.04755. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

We introduce iMED, the first synchronized multi-endoscope dataset for robot-assisted minimally invasive surgery (RAMIS), designed to address a fundamental limitation in surgical vision benchmarking: the absence of independent held-out viewpoints. Existing surgical datasets capture single-trajectory sequences from a single endoscope, making it impossible to distinguish geometric generalization from photometric interpolation along a narrow forward-facing path. iMED provides 340 sequences ~170K synchronized timepoints with 4 views per timepoint) recorded simultaneously from two independent stereo endoscopes across ex vivo, postmortem, and live surgical settings, spanning 14 specimens with diverse anatomical regions and motion regimes. The dataset includes calibrated camera intrinsics, ArUco-based frame-wise pose estimates with uncertainty quantification, instrument segmentation masks, and rich clinical metadata. Using a train-on-one-endoscope, test-on-another evaluation protocol, we benchmark 23 state-of-the-art methods across rigid and deformable novel view synthesis, pose estimation, feature matching, and monocular depth estimation. Our experiments show that methods relying primarily on photometric supervision degrade substantially under this held-out-endoscope setting, while methods with explicit geometric regularization are more robust across views in our benchmark. Notably, large-scale foundation models transfer surprisingly well to surgical imagery, often outperforming domain-specific models, suggesting pitfalls in current fine-tuning protocols. iMED establishes a new evaluation protocol for geometric generalization in surgical vision.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2611.04755 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-04T18:39:37.537Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).