Metraipolis › archive › dc_73cd57f67563
Quantifying the Unintentional Islanding Risk: A Comparative Study on Active Distribution Network — arXiv:2609.11400
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.11400
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T07:13:42.511Z
- SHA-256 of the archived text
6449c77d292c53f35746711b6e05adad179c8005710dad385637d94af6757dd1- Stable URL of this page
https://metraipolis.com/documento/dc_73cd57f67563
How to cite
Quantifying the Unintentional Islanding Risk: A Comparative Study on Active Distribution Network — arXiv:2609.11400 — arXiv (en), https://arxiv.org/abs/2609.11400 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_73cd57f67563 (Metraipolis archive dc_73cd57f67563, sha256 6449c77d292c53f35746711b6e05adad179c8005710dad385637d94af6757dd1)
BibTeX
@misc{dc73cd57f67563,
title = {Quantifying the Unintentional Islanding Risk: A Comparative Study on Active Distribution Network — arXiv:2609.11400},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.11400},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_73cd57f67563; sha256 6449c77d292c53f35746711b6e05adad179c8005710dad385637d94af6757dd1},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.11400. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
The growing share of Inverter-Based Resources (IBRs) is changing the operation of modern Active Distribution Networks (ADNs), raising concerns for grid stability, protection, and reliability. In this paper, we investigate the dynamic behavior of a Medium-Voltage (MV) portion of an ADN during the transition from grid-connected to islanded operation. The study considers a Grid-Following (GFL) converter and Synchronous Generators (SGs) operated under two distinct regulation modes: a fixed-setpoint, non-regulating condition representative of present-day distribution networks, and an active frequency/voltage-regulating condition representative of SGs equipped with governor and AVR control. Detailed electromagnetic transient (EMT) models of both technologies have been developed in DIgSILENT PowerFactory that quantifies the sensitivity of island persistence to SG regulation mode and inertia. The results show that when DERs operate at a fixed power setpoint, the risk of forming a sustained, undetected electrical island is limited, since the isolated network drifts out of the protection thresholds within tens of seconds. Conversely, enabling frequency and voltage regulation on the SGs is sufficient to sustain an unintentional island indefinitely without triggering conventional protection, regardless of system inertia. Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-09-11 in eess.SY). Categorie arXiv: Systems and Control (eess.SY). Pagina del lavoro: https://arxiv.org/abs/2609.11400 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T06:56:38.765Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-09-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).