Metraipolis › archive › dc_73b28b28d405
TRUE-Colon: Exposing a Consistent Transfer Asymmetry in Real-Time Polyp Detection — arXiv:2608.13711
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.13711
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-19T02:30:46.281Z
- SHA-256 of the archived text
1c6b3f70827c981dcebaa177b32b988b2b31d8fbec3bd282284fb9443d5e0891- Stable URL of this page
https://metraipolis.com/documento/dc_73b28b28d405
How to cite
TRUE-Colon: Exposing a Consistent Transfer Asymmetry in Real-Time Polyp Detection — arXiv:2608.13711 — arXiv (en), https://arxiv.org/abs/2608.13711 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_73b28b28d405 (Metraipolis archive dc_73b28b28d405, sha256 1c6b3f70827c981dcebaa177b32b988b2b31d8fbec3bd282284fb9443d5e0891)
BibTeX
@misc{dc73b28b28d405,
title = {TRUE-Colon: Exposing a Consistent Transfer Asymmetry in Real-Time Polyp Detection — arXiv:2608.13711},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.13711},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_73b28b28d405; sha256 1c6b3f70827c981dcebaa177b32b988b2b31d8fbec3bd282284fb9443d5e0891},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.13711. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Computer-aided detection (CADe) systems for colonoscopy promise to reduce clinical miss rates, yet reliable real-world deployment remains elusive. This translational gap stems in part from a structural flaw in model development: the reliance on curated datasets that under-represent the long negative stretches and procedure-related artifacts characteristic of routine examinations. Training and evaluating architectures strictly on these lesion-centric benchmarks creates an illusion of success, since such benchmarks cannot capture clinically crucial metrics. To expose this gap, we establish TRUE-Colon, a standardized benchmarking protocol that measures key deployment characteristics alongside localization accuracy, and evaluate four real-time architectures (Faster R-CNN, YOLOv8, YOLOv11, RT-DETR) across curated benchmarks (SUN, PICCOLO) and 60 unedited, full-length procedures (REAL-Colon). We observe a consistent transfer asymmetry: models trained strictly on curated clips suffer a severe performance collapse when evaluated on full procedures, whereas procedure-trained models substantially improve rejection of non-polyp content on REAL-Colon, and largely retain their accuracy on curated benchmarks. Beyond transferability, we find that the Transformer detector attains the strongest sensitivity and the earliest, most persistent detections, while the convolutional detectors stay competitive at a higher throughput. Together, these results indicate that both training and benchmarking for deployable CADe should shift from curated, lesion-centric clips toward full-procedure data and deployment-relevant operating points. Source code is available at this https URL . Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-08-17 in cs.LG). Categorie arXiv: Image and Video Processing (eess.IV) ; Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG). Pagina del lavoro: https://arxiv.org/abs/2608.13711 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-19T02:26:17.821Z dalla pagina https://arxiv.org/catchup/cs.LG/2026-08-17?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).