Metraipolis › archive › dc_72c37ba73b45
Two-Parameter Flow Map Learning for Continuous-Time Diffeomorphic Image Registration — arXiv:2609.10789
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.10789
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T06:28:53.167Z
- SHA-256 of the archived text
379e15bec9735d5ad9f46e3f4a8700186d83dd2a998d9a299f728a2a3fa0bc23- Stable URL of this page
https://metraipolis.com/documento/dc_72c37ba73b45
How to cite
Two-Parameter Flow Map Learning for Continuous-Time Diffeomorphic Image Registration — arXiv:2609.10789 — arXiv (en), https://arxiv.org/abs/2609.10789 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_72c37ba73b45 (Metraipolis archive dc_72c37ba73b45, sha256 379e15bec9735d5ad9f46e3f4a8700186d83dd2a998d9a299f728a2a3fa0bc23)
BibTeX
@misc{dc72c37ba73b45,
title = {Two-Parameter Flow Map Learning for Continuous-Time Diffeomorphic Image Registration — arXiv:2609.10789},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.10789},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_72c37ba73b45; sha256 379e15bec9735d5ad9f46e3f4a8700186d83dd2a998d9a299f728a2a3fa0bc23},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.10789. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Diffeomorphic image registration is central to medical image analysis, enabling anatomically consistent alignment across subjects. Most learning-based diffeomorphic methods model autonomous ODEs(ordinary differential equations) by parameterizing a stationary velocity field and recovering deformations via scaling-and-squaring. While non-autonomous ODEs with time-dependent velocities increase expressiveness, existing approaches rely on numerical integration to implicitly enforce flow structure that entangles model expressiveness with discretization accuracy. We propose a framework to directly learn the continuous-time solution of a non-autonomous ODE formulated as a two-parameterflow map. By enforcing cocycle consistency, a fundamental structural property of time-varying flows, we learn the flow maps without time discretization and velocity integration during training. The framework recovers diffeomorphic mappings at inference using a small number of compositions. Our proposed framework seamlessly incorporates standard registration backbones and improves alignment accuracy consistently across nine datasets while preserving diffeomorphic structure. Notably, the proposed method achieves an average Dice improvement of 2.1% on brain MRI benchmarks, a 12% TRE reduction on lung CT, and a 2.6% Dice gain on cardiac MRI and ultrasound datasets. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-11 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2609.10789 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T06:06:28.742Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).