Metraipolis › archive › dc_7119cdfd4e9b

Modular Model Order Reduction for Inverter-Based Power Systems with Stability and Accuracy Guarantees — arXiv:2610.02477

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.02477
License (as archived)
CC0-1.0
Archived
2026-10-06T11:41:38.560Z
SHA-256 of the archived text
c37998dd3549208c81666dce7b3368a900cdb9df78a6109da8fbbdbf663ad98d
Stable URL of this page
https://metraipolis.com/documento/dc_7119cdfd4e9b

How to cite

Modular Model Order Reduction for Inverter-Based Power Systems with Stability and Accuracy Guarantees — arXiv:2610.02477 — arXiv (en), https://arxiv.org/abs/2610.02477 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_7119cdfd4e9b (Metraipolis archive dc_7119cdfd4e9b, sha256 c37998dd3549208c81666dce7b3368a900cdb9df78a6109da8fbbdbf663ad98d)
BibTeX
@misc{dc7119cdfd4e9b,
  title = {Modular Model Order Reduction for Inverter-Based Power Systems with Stability and Accuracy Guarantees — arXiv:2610.02477},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.02477},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_7119cdfd4e9b; sha256 c37998dd3549208c81666dce7b3368a900cdb9df78a6109da8fbbdbf663ad98d},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.02477. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

This paper proposes a modular model order reduction framework for large-scale power grids integrated with renewable energy sources. The proposed framework has the advantage of reducing individual sub-areas independently while retaining the power grid interconnection structure. Moreover, given a user-defined accuracy specification on the overall reduced-order interconnected power grid, corresponding target specifications for the individual reduced sub-areas are determined: satisfaction of such individual specifications guarantees the overall user-defined accuracy specification, while also preserving the stability of the overall reduced-order interconnected power grid. The proposed framework is validated on a modified IEEE 118-bus system (where synchronous generators have been replaced by inverter-based resources) by assessing the accuracy specification satisfaction of the overall reduced-order interconnected power grid, in terms of frequency response, stability, active power, and sub-synchronous behaviour when injected with disturbances.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-10-05 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2610.02477 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-06T10:05:37.578Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-10-05?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).