Metraipolis › archive › dc_6f1ec2dd4f6b

A Modular State-Machine Based Event PID Controller — arXiv:2609.40152

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.40152
License (as archived)
CC0-1.0
Archived
2026-10-07T16:05:24.995Z
SHA-256 of the archived text
efb84a03e72b39766b59f233b1eb735a25b2a589a89085510969907fc5f1a67f
Stable URL of this page
https://metraipolis.com/documento/dc_6f1ec2dd4f6b

How to cite

A Modular State-Machine Based Event PID Controller — arXiv:2609.40152 — arXiv (en), https://arxiv.org/abs/2609.40152 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6f1ec2dd4f6b (Metraipolis archive dc_6f1ec2dd4f6b, sha256 efb84a03e72b39766b59f233b1eb735a25b2a589a89085510969907fc5f1a67f)
BibTeX
@misc{dc6f1ec2dd4f6b,
  title = {A Modular State-Machine Based Event PID Controller — arXiv:2609.40152},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.40152},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6f1ec2dd4f6b; sha256 efb84a03e72b39766b59f233b1eb735a25b2a589a89085510969907fc5f1a67f},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.40152. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

In this paper, we present a modular proportional-integral-derivative (PID) controller whose computation and mode logic are executed by a higher-level state machine. Inspired by real-time safety-critical applications where computational load, actuator chattering, sensing error and noise are design challenges, the proposed algorithm wraps a standard PID inside a finite state machine with three states (pidInit, ErrorOutRange, ErrorInRange). The goal is to regulate a desired reference within a safe region of operation while reducing actuator chattering and creating a sizable hold band over the range of operation. This design is modular and can be easily integrated into a higher-level state machine with multiple low-level loops and states. The algorithm also has low computational complexity and is suitable for embedded hardware deployment. We demonstrate the effectiveness of the algorithm in simulation on the two test benches of a published event-based PID benchmark. The algorithm computes the control updates significantly less often than the time-triggered PID and less often than both dominant event-driven controllers, while keeping a fairly equivalent control performance profile. Furthermore, we also present some experimental results of the designed algorithm for a real-time flow control.

Tema degli esploratori: calcolo e infrastrutture (retro-catalogo arXiv: annunci del 2026-10-01 in eess.SY).
Categorie arXiv: Systems and Control (eess.SY).
Pagina del lavoro: https://arxiv.org/abs/2609.40152 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-07T15:38:32.049Z dalla pagina https://arxiv.org/catchup/eess.SY/2026-10-01?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).