Metraipolis › archive › dc_6eb0683d37f1

UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound — arXiv:2609.11506

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.11506
License (as archived)
CC0-1.0
Archived
2026-10-16T06:35:41.267Z
SHA-256 of the archived text
e576e963e580cd5c980ac16e319dbd5ab147f3db502f62bad3db8eccc4db64c0
Stable URL of this page
https://metraipolis.com/documento/dc_6eb0683d37f1

How to cite

UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound — arXiv:2609.11506 — arXiv (en), https://arxiv.org/abs/2609.11506 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6eb0683d37f1 (Metraipolis archive dc_6eb0683d37f1, sha256 e576e963e580cd5c980ac16e319dbd5ab147f3db502f62bad3db8eccc4db64c0)
BibTeX
@misc{dc6eb0683d37f1,
  title = {UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound — arXiv:2609.11506},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.11506},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6eb0683d37f1; sha256 e576e963e580cd5c980ac16e319dbd5ab147f3db502f62bad3db8eccc4db64c0},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.11506. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Three-dimensional ultrasound (US) is a safe, radiation-free complementary modality to CT and X-rays for longitudinal monitoring, yet its segmentation-derived partial point clouds are extremely artifact-laden. Consequently, it is challenging to recover a clean and complete anatomical structure from such US point clouds. In this paper, we present UBone3D, a novel framework based on physics-rectified conditional flow matching (CFM) that performs point cloud completion directly from partial US observations. UBone3D models deterministic physics artifacts (e.g., surface thickening, streaking, dropouts) via a simulated physics proxy, and introduces test-time physics rectification to steer the shape completion. At inference, the completion is jointly steered by two decoupled forces: (1) anatomical plausibility enforced by a CT-trained generative shape prior, BoneFM, and (2) physics consistency enforced by USimNet in the ultrasound formation space. Extensive experiments on simulated and in-vivo data demonstrate significant improvements in reconstruction accuracy and anatomical fidelity over existing baselines.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-11 in cs.CV).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2609.11506 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T06:06:28.789Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).