Metraipolis › archive › dc_6eb0683d37f1
UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound — arXiv:2609.11506
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.11506
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T06:35:41.267Z
- SHA-256 of the archived text
e576e963e580cd5c980ac16e319dbd5ab147f3db502f62bad3db8eccc4db64c0- Stable URL of this page
https://metraipolis.com/documento/dc_6eb0683d37f1
How to cite
UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound — arXiv:2609.11506 — arXiv (en), https://arxiv.org/abs/2609.11506 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6eb0683d37f1 (Metraipolis archive dc_6eb0683d37f1, sha256 e576e963e580cd5c980ac16e319dbd5ab147f3db502f62bad3db8eccc4db64c0)
BibTeX
@misc{dc6eb0683d37f1,
title = {UBone3D: Physics-Rectified Conditional Flow Matching for Anatomical 3D Shape Completion from Ultrasound — arXiv:2609.11506},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.11506},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6eb0683d37f1; sha256 e576e963e580cd5c980ac16e319dbd5ab147f3db502f62bad3db8eccc4db64c0},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.11506. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Three-dimensional ultrasound (US) is a safe, radiation-free complementary modality to CT and X-rays for longitudinal monitoring, yet its segmentation-derived partial point clouds are extremely artifact-laden. Consequently, it is challenging to recover a clean and complete anatomical structure from such US point clouds. In this paper, we present UBone3D, a novel framework based on physics-rectified conditional flow matching (CFM) that performs point cloud completion directly from partial US observations. UBone3D models deterministic physics artifacts (e.g., surface thickening, streaking, dropouts) via a simulated physics proxy, and introduces test-time physics rectification to steer the shape completion. At inference, the completion is jointly steered by two decoupled forces: (1) anatomical plausibility enforced by a CT-trained generative shape prior, BoneFM, and (2) physics consistency enforced by USimNet in the ultrasound formation space. Extensive experiments on simulated and in-vivo data demonstrate significant improvements in reconstruction accuracy and anatomical fidelity over existing baselines. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-11 in cs.CV). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Image and Video Processing (eess.IV). Pagina del lavoro: https://arxiv.org/abs/2609.11506 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-16T06:06:28.789Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-09-11?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).