Metraipolis › archive › dc_6e8747651d72

Highly accelerated 3D Cartesian MPnRAGE with implicit neural representation reconstruction — arXiv:2609.18589

Source
arXiv (en)
Original
https://arxiv.org/abs/2609.18589
License (as archived)
CC0-1.0
Archived
2026-10-15T18:31:07.518Z
SHA-256 of the archived text
7ab6760d7a38b947e31dd054db5541bf547e1fbfcfac9dfb765cfc898e55af8a
Stable URL of this page
https://metraipolis.com/documento/dc_6e8747651d72

How to cite

Highly accelerated 3D Cartesian MPnRAGE with implicit neural representation reconstruction — arXiv:2609.18589 — arXiv (en), https://arxiv.org/abs/2609.18589 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6e8747651d72 (Metraipolis archive dc_6e8747651d72, sha256 7ab6760d7a38b947e31dd054db5541bf547e1fbfcfac9dfb765cfc898e55af8a)
BibTeX
@misc{dc6e8747651d72,
  title = {Highly accelerated 3D Cartesian MPnRAGE with implicit neural representation reconstruction — arXiv:2609.18589},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2609.18589},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6e8747651d72; sha256 7ab6760d7a38b947e31dd054db5541bf547e1fbfcfac9dfb765cfc898e55af8a},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.18589. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

MPnRAGE enables multiple inversion contrast images in a single scan, allowing quantitative T1 mapping, tissue nulled contrasts, and standard MPRAGE synthesis. However, current 3D scan times remain clinically impractical, motivating accelerated 3D MPnRAGE. This work provides a highly accelerated Cartesian 3D MPnRAGE sequence with joint implicit neural representation (INR) reconstruction. The sequence uses a tailored view-ordering strategy, flip angle schedule and complementary variable-density Poisson-disk undersampling. Calibration data acquired during otherwise unused delay time are used for sensitivity map estimation and complementary high-frequency sampling. Ten INR-reconstructed inversion images at 1.5 mm$^3$ are evaluated against fully sampled references via retrospective undersampling. Prospectively accelerated 1 mm$^3$ images at R = 20 (5.39 min) demonstrate clinical feasibility. INR reconstruction outperforms subspace and iterative local low rank reconstruction on highly accelerated data. The proposed highly undersampled 3D Cartesian MPnRAGE with INR reconstruction generates multiple high-quality inversion contrasts in substantially reduced scan time. Scan-specific INR reconstruction improves image quality while reducing reconstruction time versus state-of-the-art methods.

Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-09-17 in eess.IV).
Categorie arXiv: Image and Video Processing (eess.IV).
Pagina del lavoro: https://arxiv.org/abs/2609.18589 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-15T18:00:31.620Z dalla pagina https://arxiv.org/catchup/eess.IV/2026-09-17?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).