Metraipolis › archive › dc_6e267f7db65d

Switchable resolution in soft x-ray tomography of single cells — Europe PMC PMID:31978064

Source
Europe PMC (en)
Original
https://europepmc.org/article/MED/31978064
DOI
10.1371/journal.pone.0227601
License (as archived)
CC0-1.0
Archived
2026-11-09T15:46:40.256Z
SHA-256 of the archived text
2588f16f72e2b4e0192f7f49926fae01acfe1e917a9aa56002225af48c969d39
Stable URL of this page
https://metraipolis.com/documento/dc_6e267f7db65d

How to cite

Switchable resolution in soft x-ray tomography of single cells — Europe PMC PMID:31978064 — Europe PMC (en), https://europepmc.org/article/MED/31978064 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6e267f7db65d (Metraipolis archive dc_6e267f7db65d, sha256 2588f16f72e2b4e0192f7f49926fae01acfe1e917a9aa56002225af48c969d39)
BibTeX
@misc{dc6e267f7db65d,
  title = {Switchable resolution in soft x-ray tomography of single cells — Europe PMC PMID:31978064},
  howpublished = {Europe PMC (en)},
  url = {https://europepmc.org/article/MED/31978064},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6e267f7db65d; sha256 2588f16f72e2b4e0192f7f49926fae01acfe1e917a9aa56002225af48c969d39},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/31978064. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

The diversity of living cells, in both size and internal complexity, calls for imaging methods with adaptable spatial resolution. Soft x-ray tomography (SXT) is a three-dimensional imaging technique ideally suited to visualizing and quantifying the internal organization of single cells of varying sizes in a near-native state. The achievable resolution of the soft x-ray microscope is largely determined by the objective lens, but switching between objectives is extremely time-consuming and typically undertaken only during microscope maintenance procedures. Since the resolution of the optic is inversely proportional to the depth of focus, an optic capable of imaging the thickest cells is routinely selected. This unnecessarily limits the achievable resolution in smaller cells and eliminates the ability to obtain high-resolution images of regions of interest in larger cells. Here, we describe developments to overcome this shortfall and allow selection of microscope optics best suited to the specimen characteristics and data requirements. We demonstrate that switchable objective capability advances the flexibility of SXT to enable imaging cells ranging in size from bacteria to yeast and mammalian cells without physically modifying the microscope, and we demonstrate the use of this technology to image the same specimen with both optics.

Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera).
Pubblicazione: PloS one, 2020 (prima pubblicazione 2020-01-24).
Identificativi: PMID 31978064 · PMCID PMC6980406 · DOI 10.1371/journal.pone.0227601.