Metraipolis › archive › dc_6defec1a32cb
A Master-to-Simulation Interface with Demonstration-Trajectory Guidance for Vascular Intervention — arXiv:2610.19395
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.19395
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-15T21:57:47.357Z
- SHA-256 of the archived text
34da5903b39bd58d99b58775ec5a4ae8fdc0af426e9bb0fc71aa0be5bd26874d- Stable URL of this page
https://metraipolis.com/documento/dc_6defec1a32cb
How to cite
A Master-to-Simulation Interface with Demonstration-Trajectory Guidance for Vascular Intervention — arXiv:2610.19395 — arXiv (en), https://arxiv.org/abs/2610.19395 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6defec1a32cb (Metraipolis archive dc_6defec1a32cb, sha256 34da5903b39bd58d99b58775ec5a4ae8fdc0af426e9bb0fc71aa0be5bd26874d)
BibTeX
@misc{dc6defec1a32cb,
title = {A Master-to-Simulation Interface with Demonstration-Trajectory Guidance for Vascular Intervention — arXiv:2610.19395},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.19395},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6defec1a32cb; sha256 34da5903b39bd58d99b58775ec5a4ae8fdc0af426e9bb0fc71aa0be5bd26874d},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.19395. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Robotic vascular intervention can reduce radiation exposure to physicians and improve manipulation stability, but effective guidance remains challenging because conventional fluoroscopic images provide limited spatial information. This paper developed a vascular intervention interactive system that connects a real robotic master controller with the SOFA(Simulation Open Framework Architecture) physical simulation platform and reused successful operation trajectories as visual guidance in physical phantom experiments. Experiments were conducted to validate the master-to-SOFA control loop and to compare three guidance conditions: no guidance, centerline guidance, and successful-trajectory guidance. The control validation results showed reliable command delivery under velocity-mode operation. In the physical phantom experiment, centerline guidance showed no obvious improvement over no guidance. In contrast, successful trajectory guidance provided a clear performance benefit. Compared with the no-guidance condition, it reduced task completion time, collision number, rollback number, and rotation number by approximately 66.8%, 34.3%, 55.6%, and 66.7%, respectively. These results indicate that successful trajectories obtained under instrument-vessel interaction can provide practical guidance cues, offering a simple and effective visual assistance strategy for robotic vascular intervention experiments. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.RO, nuovi lavori del giorno). Categorie arXiv: Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2610.19395 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-15T21:38:44.440Z dalla pagina https://arxiv.org/list/cs.RO/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).