Metraipolis › archive › dc_6d0a2adca6c7

CortexBridge: Cortical Alignment of EEG Montages for Foundation Models — arXiv:2610.01124

Source
arXiv (en)
Original
https://arxiv.org/abs/2610.01124
License (as archived)
CC0-1.0
Archived
2026-10-06T12:03:52.874Z
SHA-256 of the archived text
5c0524f99527e38b827ef3aff752b96fb9d7499abbce59c62123c4ed9fd895a7
Stable URL of this page
https://metraipolis.com/documento/dc_6d0a2adca6c7

How to cite

CortexBridge: Cortical Alignment of EEG Montages for Foundation Models — arXiv:2610.01124 — arXiv (en), https://arxiv.org/abs/2610.01124 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6d0a2adca6c7 (Metraipolis archive dc_6d0a2adca6c7, sha256 5c0524f99527e38b827ef3aff752b96fb9d7499abbce59c62123c4ed9fd895a7)
BibTeX
@misc{dc6d0a2adca6c7,
  title = {CortexBridge: Cortical Alignment of EEG Montages for Foundation Models — arXiv:2610.01124},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2610.01124},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6d0a2adca6c7; sha256 5c0524f99527e38b827ef3aff752b96fb9d7499abbce59c62123c4ed9fd895a7},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.01124. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Electroencephalography (EEG) foundation models are often pretrained with a fixed channel vocabulary or a limited set of montages, making transfer difficult when electrode layouts change. We propose CortexBridge, a lightweight adapter that combines EEG features with electrode and atlas coordinates to map arbitrary montages into a shared cortical latent space. Evaluated with three frozen foundation models on five brain-computer interface (BCI) datasets from the Mother of All BCI Benchmarks (MOABB), CortexBridge improves performance in 13 of 15 evaluations. The gains in balanced accuracy average 0.80% for EEGPT, 0.70% for LaBraM, and 3.26% for CBraMod, with a maximum gain of 13.02% on 12-class steady-state visual evoked potential (SSVEP) classification. Visualizations of the learned atlas representations reveal task-dependent spatial patterns, with SSVEP showing a more concentrated representation in the Yeo Visual network than auditory P300. These results establish cortical alignment as a learnable and anatomically grounded routing mechanism from heterogeneous EEG montages to pretrained foundation models.

Tema degli esploratori: agenti e intelligenza artificiale (retro-catalogo arXiv: annunci del 2026-10-02 in cs.AI).
Categorie arXiv: Artificial Intelligence (cs.AI) ; Signal Processing (eess.SP).
Pagina del lavoro: https://arxiv.org/abs/2610.01124 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-06T10:21:27.916Z dalla pagina https://arxiv.org/catchup/cs.AI/2026-10-02?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).