Metraipolis › archive › dc_6c9541b63c6b
Open-Source Framework for the Visualization, Quantification, and Analysis of 4D Flow and High-Dimensional Magnetic Resonance Images — arXiv:2610.38948
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2610.38948
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-01T02:58:39.817Z
- SHA-256 of the archived text
9d623b57323bf2acd3dff9c6c1972d3bac5c005a1f2fc8b4b3ca6fd2ed6134e5- Stable URL of this page
https://metraipolis.com/documento/dc_6c9541b63c6b
How to cite
Open-Source Framework for the Visualization, Quantification, and Analysis of 4D Flow and High-Dimensional Magnetic Resonance Images — arXiv:2610.38948 — arXiv (en), https://arxiv.org/abs/2610.38948 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6c9541b63c6b (Metraipolis archive dc_6c9541b63c6b, sha256 9d623b57323bf2acd3dff9c6c1972d3bac5c005a1f2fc8b4b3ca6fd2ed6134e5)
BibTeX
@misc{dc6c9541b63c6b,
title = {Open-Source Framework for the Visualization, Quantification, and Analysis of 4D Flow and High-Dimensional Magnetic Resonance Images — arXiv:2610.38948},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2610.38948},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6c9541b63c6b; sha256 9d623b57323bf2acd3dff9c6c1972d3bac5c005a1f2fc8b4b3ca6fd2ed6134e5},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2610.38948. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Background: Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) captures 3D anatomy and blood velocity across the cardiac cycle, but current post-processing software is closed, varies across platforms, and sits outside open-source image-computing frameworks. We developed an open-source framework for the import, visualization, and quantification of 4D flow and other high-dimensional CMR within SlicerHeart, an extension for 3D Slicer. Methods: Import 4D Flow reads vendor DICOM, applies preprocessing, and stores velocities as a time-resolved vector field; Analyze 4D Flow provides measurement planes, streamline and Doppler-like visualization, segmentation propagation, and quantification. Underlying both, we extended the Insight Toolkit to store five- and higher-dimensional arrays. Flow quantification was compared with a commercial package (cvi42) and 2D phase contrast in 13 patients with congenital heart disease across 108 paired regions of interest (Bland-Altman analysis and intraclass correlation coefficients, ICCs). Consensus-recommended processing methods were also implemented as an open-source library with an automated test suite of analytic and CFD phantoms and clinical acquisitions. Results: The modules integrate with 3D Slicer's segmentation, registration, and rendering tools and export velocity fields and geometry for computational modeling. Agreement with cvi42 was close: forward volume bias -0.1 mL (95% limits of agreement 2.2 to -2.3; ICC 0.997), effective volume per minute bias -0.015 L/min (0.21 to -0.24; ICC 0.994). Against 2D phase contrast, forward volume bias (-2.2 mL) and mean absolute percentage error (21.8%) matched cvi42 (-2.1 mL; 21.3%). Conclusions: This open, extensible framework brings 4D flow CMR into an established image-computing ecosystem and agrees closely with a commercial reference; every step can be inspected, reproduced, and improved. Tema degli esploratori: scienze della vita e salute (elenco arXiv q-bio.QM, nuovi lavori del giorno). Categorie arXiv: Quantitative Methods (q-bio.QM). Pagina del lavoro: https://arxiv.org/abs/2610.38948 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-01T02:23:28.360Z dalla pagina https://arxiv.org/list/q-bio.QM/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).