Metraipolis › archive › dc_6c08391d124e
USB Gym: A Gymnasium Testbed for Closed-Loop Ultrasound View Matching — arXiv:2611.08352
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.08352
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-06T14:51:20.867Z
- SHA-256 of the archived text
4acccce78e2f985fbbfc6170b6ec86e5d30c1bfb4139f4c454b2f290e0a6ed7f- Stable URL of this page
https://metraipolis.com/documento/dc_6c08391d124e
How to cite
USB Gym: A Gymnasium Testbed for Closed-Loop Ultrasound View Matching — arXiv:2611.08352 — arXiv (en), https://arxiv.org/abs/2611.08352 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6c08391d124e (Metraipolis archive dc_6c08391d124e, sha256 4acccce78e2f985fbbfc6170b6ec86e5d30c1bfb4139f4c454b2f290e0a6ed7f)
BibTeX
@misc{dc6c08391d124e,
title = {USB Gym: A Gymnasium Testbed for Closed-Loop Ultrasound View Matching — arXiv:2611.08352},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.08352},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6c08391d124e; sha256 4acccce78e2f985fbbfc6170b6ec86e5d30c1bfb4139f4c454b2f290e0a6ed7f},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.08352. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Background and Objective: Our main goal is ultrasound guidance: moving a probe until its image matches a target view. Published methods for each part of a guide are evaluated in separate simulators. We asked whether these methods, combined into one guide, are good enough. Methods: We built USB Gym, a testbed whose standard engine simulates ultrasound from public patient CT, with a network drawing organ textures from CT labels. Its guide has three replaceable parts (slots), an organ segmenter, a controller and a reward, which received 20 published methods, each run on the same 60 episodes of six held-out patients. In each slot, a published method replaced ours only if detectably better on these patients. The better of this combination and our original guide on 20 new CTs is the benchmark baseline. A pose oracle, reading the exact probe pose available only in simulation, set the reference. The results below are exploratory. Results: On these CTs, the probe started on average 16.0 mm from the target view; the pose oracle brought it to 1.5 mm. Of the results known when the combination was fixed, only an image-similarity reward (SSIM) was slightly but detectably better, so the combination was our guide with that reward. This combination was the benchmark baseline, ending at 13.7 mm (16% of the oracle's progress). Conclusions: Combining untuned published methods with ours did not guide the probe near the target view; the task remains under-explored. The testbed accepts new methods; no guide was tested on hardware. Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.LG, nuovi lavori del giorno). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Machine Learning (cs.LG); Robotics (cs.RO). Pagina del lavoro: https://arxiv.org/abs/2611.08352 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-06T14:21:42.670Z dalla pagina https://arxiv.org/list/cs.LG/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).