Metraipolis › archive › dc_6b6a3c35c9be

Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI — arXiv:2611.04053

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.04053
License (as archived)
CC0-1.0
Archived
2026-11-04T12:56:08.944Z
SHA-256 of the archived text
2ab85d20d79edc237a37bc677fcb17cef03f7957fb081b661fa3b5ddb55bb7f2
Stable URL of this page
https://metraipolis.com/documento/dc_6b6a3c35c9be

How to cite

Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI — arXiv:2611.04053 — arXiv (en), https://arxiv.org/abs/2611.04053 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6b6a3c35c9be (Metraipolis archive dc_6b6a3c35c9be, sha256 2ab85d20d79edc237a37bc677fcb17cef03f7957fb081b661fa3b5ddb55bb7f2)
BibTeX
@misc{dc6b6a3c35c9be,
  title = {Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI — arXiv:2611.04053},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.04053},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6b6a3c35c9be; sha256 2ab85d20d79edc237a37bc677fcb17cef03f7957fb081b661fa3b5ddb55bb7f2},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.04053. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Intracardiac flow is driven by complex, and time-varying cardiac motion and interaction with the heart valves, producing complex flow features that may provide valuable information for disease diagnosis and treatment planning. 4D Flow MRI enables non-invasive, time-resolved measurement of three-dimensional cardiovascular velocity fields. However, substantial noise and limited spatial and temporal resolution limit its ability to accurately resolve flow features. We propose 4D-MRAR (4D Magnetic Resonance Augmented Reconstruction), a deep learning (DL) method to super-resolve and denoise 4D Flow MRI data. Unlike prior DL methods that train and infer on static vascular regions, our method predicts intracardiac flow within hearts undergoing large deformation. Moreover, it uniquely allows for simultaneous super-resolution in 3D space and time. The method combines a residual convolutional neural network, a recurrent neural network, and an implicit neural field to predict high-resolution velocity and pressure fields while efficiently enforcing the governing equations of fluid flow during training. Trained on a synthetic dataset obtained from computational fluid dynamics (CFD) simulations of left ventricle (LV) flow, our method generalizes to synthetic whole-heart 4D flow MRI data, and demonstrated promising performance on real 4D Flow MRI. The produced super-resolved flow fields exhibit significantly improved accuracy and greater consistency with the governing equations of blood flow compared with prior methods.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno).