Metraipolis › archive › dc_6afae2a6b906
Spatially and Compositionally Controlled Multimodal Glioblastoma MRI Synthesis with Latent Diffusion — arXiv:2611.06540
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2611.06540
- License (as archived)
- CC0-1.0
- Archived
- 2026-11-05T18:30:06.006Z
- SHA-256 of the archived text
18e7cff34b6186dbe77ab2f1878b3a1a5094e60de5aa610321ee952bfc0849d5- Stable URL of this page
https://metraipolis.com/documento/dc_6afae2a6b906
How to cite
Spatially and Compositionally Controlled Multimodal Glioblastoma MRI Synthesis with Latent Diffusion — arXiv:2611.06540 — arXiv (en), https://arxiv.org/abs/2611.06540 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6afae2a6b906 (Metraipolis archive dc_6afae2a6b906, sha256 18e7cff34b6186dbe77ab2f1878b3a1a5094e60de5aa610321ee952bfc0849d5)
BibTeX
@misc{dc6afae2a6b906,
title = {Spatially and Compositionally Controlled Multimodal Glioblastoma MRI Synthesis with Latent Diffusion — arXiv:2611.06540},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2611.06540},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6afae2a6b906; sha256 18e7cff34b6186dbe77ab2f1878b3a1a5094e60de5aa610321ee952bfc0849d5},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.06540. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Glioblastoma exhibits substantial heterogeneity in tumour morphology and composition across MRI modalities, often making available clinical datasets highly unbalanced in terms of patient pathologies. We propose a two-stage latent diffusion model (LDM) framework for the generation of explicitly controllable 2D glioblastoma MRI scans. First, a segmentation LDM generates tumour maps conditioned on location, spatial extent, axial position, and subregion composition. Second, a modality-conditioned LDM with ControlNet generates T1, T1Gd, T2, and FLAIR images adhering to the requested segmentation. On a held-out test set, generated segmentations achieved a mean centroid error of 0.842 pixels and a subregion proportion error of 0.795 percentage points. ControlNet improved Fréchet inception distance (FID) across all four modalities, reducing pooled FID from 42.59 to 36.12. An expert reader study yielded mean quality ratings of 6.60 for real images, 6.83 for ControlNet-generated images, and 6.77 for fully synthetic images. Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.CV, nuovi lavori del giorno). Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2611.06540 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-11-05T18:19:49.060Z dalla pagina https://arxiv.org/list/cs.CV/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).