Metraipolis › archive › dc_6ae314f6302b
Performance Comparison of the Nonlinear Curvature and Shack-Hartmann Wavefront Sensors in Strong Turbulence — arXiv:2609.10536
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2609.10536
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-16T11:36:13.417Z
- SHA-256 of the archived text
27a0fb9d1cdf9e25550bbb8e09eb30a270980b11f913562ec22539a8140832d7- Stable URL of this page
https://metraipolis.com/documento/dc_6ae314f6302b
How to cite
Performance Comparison of the Nonlinear Curvature and Shack-Hartmann Wavefront Sensors in Strong Turbulence — arXiv:2609.10536 — arXiv (en), https://arxiv.org/abs/2609.10536 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_6ae314f6302b (Metraipolis archive dc_6ae314f6302b, sha256 27a0fb9d1cdf9e25550bbb8e09eb30a270980b11f913562ec22539a8140832d7)
BibTeX
@misc{dc6ae314f6302b,
title = {Performance Comparison of the Nonlinear Curvature and Shack-Hartmann Wavefront Sensors in Strong Turbulence — arXiv:2609.10536},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2609.10536},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_6ae314f6302b; sha256 27a0fb9d1cdf9e25550bbb8e09eb30a270980b11f913562ec22539a8140832d7},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2609.10536. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Strong turbulence induces spatial variations in beam intensity that hinder the reconstruction process of many commonly deployed adaptive optics (AO) systems that use gradient-based wavefront sensors (WFS), such as the Shack-Hartmann wavefront sensor (SHWFS) and pyramid wavefront sensor. The nonlinear curvature WFS (nlCWFS) uses Fresnel diffraction to extract wavefront phase and amplitude information, suggesting that it may be able to operate under challenging turbulence conditions. In this work, we investigate nlCWFS reconstruction accuracy as a function of turbulence strength and relative flux by modeling high spherical-wave Rytov number ($R_{sw}$) environments where scintillation and branch points impact sensing performance. We present open-loop as well as static and dynamic closed-loop results benchmarked against a comparable Shack-Hartmann WFS (SHWFS). In static and weak-to-moderate scintillation regimes, the nlCWFS consistently outperforms the SHWFS by leveraging amplitude-phase coupling inaccessible to gradient-based sensors. However, dynamic closed-loop simulations reveal a crossover behavior at higher scintillation strengths, where deep intensity nulls and proliferating branch points degrade the performance of Gerchberg-Saxton-based nlCWFS reconstruction, while the SHWFS degrades more gradually due to its insensitivity to such topological phase structure. These results highlight the regime-dependent advantages of the nlCWFS and emphasize the need for branch-point-tolerant reconstruction algorithms to fully realize its potential in strong-turbulence, low-flux conditions.
Tema degli esploratori: fisica e astronomia (retro-catalogo arXiv: annunci del 2026-09-10 in astro-ph.IM).
Categorie arXiv: Instrumentation and Methods for Astrophysics (astro-ph.IM).
Pagina del lavoro: https://arxiv.org/abs/2609.10536 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-16T11:21:03.735Z dalla pagina https://arxiv.org/catchup/astro-ph.IM/2026-09-10?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).