Metraipolis › archive › dc_697ad633116c

Local2Mesh: Spatially Localized Contour-to-Mesh for Left Ventricular Reconstruction from Sparse 2D Cardiac MRI — arXiv:2610.06052

Source
arXiv
Original
https://arxiv.org/abs/2610.06052
License (as archived)
CC0-1.0
Archived
2026-10-06T05:27:24.464Z
SHA-256 of the archived text
c6d3bb9e74828cb39d441c9dbf678e73efe2ea76efc797951bc880825740c4ac
Stable URL of this page
https://metraipolis.com/documento/dc_697ad633116c

How to cite

Local2Mesh: Spatially Localized Contour-to-Mesh for Left Ventricular Reconstruction from Sparse 2D Cardiac MRI — arXiv:2610.06052 — arXiv, https://arxiv.org/abs/2610.06052 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_697ad633116c (Metraipolis archive dc_697ad633116c, sha256 c6d3bb9e74828cb39d441c9dbf678e73efe2ea76efc797951bc880825740c4ac)
BibTeX
@misc{dc697ad633116c,
  title = {Local2Mesh: Spatially Localized Contour-to-Mesh for Left Ventricular Reconstruction from Sparse 2D Cardiac MRI — arXiv:2610.06052},
  howpublished = {arXiv},
  url = {https://arxiv.org/abs/2610.06052},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_697ad633116c; sha256 c6d3bb9e74828cb39d441c9dbf678e73efe2ea76efc797951bc880825740c4ac},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv, https://arxiv.org/abs/2610.06052. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Three-dimensional (3D) left ventricular (LV) reconstruction from sparse cardiac magnetic resonance (CMR) imaging remains challenging due to inter-slice misalignment and insufficient local spatial information between slices. Global aggregation of contour features may obscure local contour-to-surface relationships. We propose Local2Mesh, a spatially localized contour-to-mesh framework that deforms a template mesh to reconstruct 3D LV geometry from sparse 2D contours without 3D mesh annotations. The framework introduces geometry-aware alignment to correct inter-slice misalignment and a plane-aware Local Router that routes contour features to template vertices using vertex-to-plane distances. Local and global contour features then jointly guide graph-based template deformation for 3D LV reconstruction. Experiments on two public datasets, M\&Ms-2 and ACDC, demonstrate superior geometric reconstruction and functional estimation over existing methods. Zero-shot transfer from M\&Ms-2 to ACDC demonstrates strong cross-dataset generalization. Reconstructed meshes also improve disease classification over sparse contours, supporting their utility for downstream cardiac analysis. These results demonstrate that combining geometry-aware alignment with local contour-to-vertex modeling improves LV reconstruction from sparse 2D contours and supports downstream cardiac analysis. The code is available at \url{ this https URL }.

Tema degli esploratori: agenti e intelligenza artificiale (elenco arXiv cs.AI, nuovi lavori del giorno).
Categorie arXiv: Computer Vision and Pattern Recognition (cs.CV) ; Artificial Intelligence (cs.AI).
Pagina del lavoro: https://arxiv.org/abs/2610.06052 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-10-06T05:24:06.111Z dalla pagina https://arxiv.org/list/cs.AI/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).