Metraipolis › archive › dc_681b3b107c2f
Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation — Europe PMC PMID:35696442
- Source
- Europe PMC (en)
- Original
- https://europepmc.org/article/MED/35696442
- DOI
- 10.1371/journal.pcbi.1010141
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-18T07:57:37.500Z
- SHA-256 of the archived text
cf0f779770dc7267af6610b791a1dd28e83f57549cfeb2c63d09a858d4a70578- Stable URL of this page
https://metraipolis.com/documento/dc_681b3b107c2f
How to cite
Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation — Europe PMC PMID:35696442 — Europe PMC (en), https://europepmc.org/article/MED/35696442 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_681b3b107c2f (Metraipolis archive dc_681b3b107c2f, sha256 cf0f779770dc7267af6610b791a1dd28e83f57549cfeb2c63d09a858d4a70578)
BibTeX
@misc{dc681b3b107c2f,
title = {Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation — Europe PMC PMID:35696442},
howpublished = {Europe PMC (en)},
url = {https://europepmc.org/article/MED/35696442},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_681b3b107c2f; sha256 cf0f779770dc7267af6610b791a1dd28e83f57549cfeb2c63d09a858d4a70578},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: Europe PMC (en), https://europepmc.org/article/MED/35696442. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Background: Left ventricular assist devices (LVADs) are implantable pumps that act as a life support therapy for patients with severe heart failure. Despite improving the survival rate, LVAD therapy can carry major complications. Particularly, the flow distortion introduced by the LVAD in the left ventricle (LV) may induce thrombus formation. While previous works have used numerical models to study the impact of multiple variables in the intra-LV stagnation regions, a comprehensive validation analysis has never been executed. The main goal of this work is to present a model of the LV-LVAD system and to design and follow a verification, validation and uncertainty quantification (VVUQ) plan based on the ASME V&V40 and V&V20 standards to ensure credible predictions. Methods: The experiment used to validate the simulation is the SDSU cardiac simulator, a bench mock-up of the cardiovascular system that allows mimicking multiple operation conditions for the heart-LVAD system. The numerical model is based on Alya, the BSC's in-house platform for numerical modelling. Alya solves the Navier-Stokes equation with an Arbitrary Lagrangian-Eulerian (ALE) formulation in a deformable ventricle and includes pressure-driven valves, a 0D Windkessel model for the arterial output and a LVAD boundary condition modeled through a dynamic pressure-flow performance curve. The designed VVUQ plan involves: (a) a risk analysis and the associated credibility goals; (b) a verification stage to ensure correctness in the numerical solution procedure; (c) a sensitivity analysis to quantify the impact of the inputs on the four quantities of interest (QoIs) (average aortic root flow [Formula: see text], maximum aortic root flow [Formula: see text], average LVAD flow [Formula: see text], and maximum LVAD flow [Formula: see text]); (d) an uncertainty quantification using six validation experiments that include extreme operating conditions. Results: Numerical code verification tests ensured correctness of the solution procedure and numerical calculation verification showed a grid convergence index (GCI)95% <3.3%. The total Sobol indices obtained during the sensitivity analysis demonstrated that the ejection fraction, the heart rate, and the pump performance curve coefficients are the most impactful inputs for the analysed QoIs. The Minkowski norm is used as validation metric for the uncertainty quantification. It shows that the midpoint cases have more accurate results when compared to the extreme cases. The total computational cost of the simulations was above 100 [core-years] executed in around three weeks time span in Marenostrum IV supercomputer. Conclusions: This work details a novel numerical model for the LV-LVAD system, that is supported by the design and execution of a VVUQ plan created following recognised international standards. We present a methodology demonstrating that stringent VVUQ according to ASME standards is feasible but computationally expensive. Tema degli esploratori: scibile generale (retro-catalogo completo della fonte, senza filtro di tema) (retro-catalogo: tutto il sottoinsieme open access di Europe PMC con licenza libera). Pubblicazione: PLoS computational biology, 2022 (prima pubblicazione 2022-06-13). Identificativi: PMID 35696442 · PMCID PMC9232142 · DOI 10.1371/journal.pcbi.1010141. Descrittori MeSH principali: Heart-Assist Devices; Heart Failure. Pagina: https://europepmc.org/article/MED/35696442 — https://doi.org/10.1371/journal.pcbi.1010141. Autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza dell'articolo dichiarata da Europe PMC: CC0 (la versione è indicata dall'editore sulla pagina). Abstract riportato senza modifiche al contenuto, con attribuzione; deposito marcato CC0. Letto il 2026-10-18T07:57:32.951Z tramite l'API REST ufficiale di Europe PMC (EMBL-EBI), nel rispetto del robots.txt e del crawl-delay.