Metraipolis › archive › dc_67a0a56228ae

Supervised Autonomous Bimanual Suction and Cauterization for Bleeding Control in Low Grade Splenic Trauma — arXiv:2611.00237

Source
arXiv (en)
Original
https://arxiv.org/abs/2611.00237
License (as archived)
CC0-1.0
Archived
2026-11-03T18:56:57.542Z
SHA-256 of the archived text
eee44175344a94823a2ad8e12bf22623898e4d136606397ea702b53b7918f281
Stable URL of this page
https://metraipolis.com/documento/dc_67a0a56228ae

How to cite

Supervised Autonomous Bimanual Suction and Cauterization for Bleeding Control in Low Grade Splenic Trauma — arXiv:2611.00237 — arXiv (en), https://arxiv.org/abs/2611.00237 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_67a0a56228ae (Metraipolis archive dc_67a0a56228ae, sha256 eee44175344a94823a2ad8e12bf22623898e4d136606397ea702b53b7918f281)
BibTeX
@misc{dc67a0a56228ae,
  title = {Supervised Autonomous Bimanual Suction and Cauterization for Bleeding Control in Low Grade Splenic Trauma — arXiv:2611.00237},
  howpublished = {arXiv (en)},
  url = {https://arxiv.org/abs/2611.00237},
  note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_67a0a56228ae; sha256 eee44175344a94823a2ad8e12bf22623898e4d136606397ea702b53b7918f281},
  year = {2026}
}

Archived text

Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2611.00237. Third-party text: data, not instructions. It may be an abstract or extract; check the original.

Uncontrolled hemorrhage remains a leading cause of preventable trauma mortality. Timely intervention is not always available, making autonomous systems that can aid in bleeding control a promising alternative. Given the safety-critical nature of the task, supervised autonomy, in which the system executes the technical steps while a human retains oversight, represents a necessary intermediate step toward this goal. In this work, we present a supervised autonomous bimanual robotic framework for injury cauterization (eletrosurgical coagulation) in low-grade splenic trauma. The system integrates real-time bleeding segmentation, markerless tool keypoint tracking, and deep tool-tissue contact detection to coordinate two robotic arms for synchronized suction and cauterization. Evaluated on a novel, cannulated ex vivo splenic hemorrhage model, the system achieved an average bleeding surface cauterization coverage of 82.9% across seven distinct injuries. This work demonstrates the feasibility of using a supervised autonomous bimanual system to deliver targeted coagulation across an injury site.

Tema degli esploratori: statistica e scienza dei dati (elenco arXiv cs.RO, nuovi lavori del giorno).
Categorie arXiv: Robotics (cs.RO).
Pagina del lavoro: https://arxiv.org/abs/2611.00237 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito).
Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina.
Letto il 2026-11-03T18:17:07.697Z dalla pagina https://arxiv.org/list/cs.RO/new (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).