Metraipolis › archive › dc_66e149842989
Generalizing Soft Tissue Deformation and Force Prediction Across Material Stiffness and Geometry — arXiv:2608.20967
- Source
- arXiv (en)
- Original
- https://arxiv.org/abs/2608.20967
- License (as archived)
- CC0-1.0
- Archived
- 2026-10-18T10:56:31.464Z
- SHA-256 of the archived text
61297908310539792a77015fba3a59c90969445ade08d91cddb7c8c9373c97be- Stable URL of this page
https://metraipolis.com/documento/dc_66e149842989
How to cite
Generalizing Soft Tissue Deformation and Force Prediction Across Material Stiffness and Geometry — arXiv:2608.20967 — arXiv (en), https://arxiv.org/abs/2608.20967 (CC0-1.0); archived copy: https://metraipolis.com/documento/dc_66e149842989 (Metraipolis archive dc_66e149842989, sha256 61297908310539792a77015fba3a59c90969445ade08d91cddb7c8c9373c97be)
BibTeX
@misc{dc66e149842989,
title = {Generalizing Soft Tissue Deformation and Force Prediction Across Material Stiffness and Geometry — arXiv:2608.20967},
howpublished = {arXiv (en)},
url = {https://arxiv.org/abs/2608.20967},
note = {License CC0-1.0; archived copy https://metraipolis.com/documento/dc_66e149842989; sha256 61297908310539792a77015fba3a59c90969445ade08d91cddb7c8c9373c97be},
year = {2026}
}Archived text
Reproduced under CC0-1.0. Attribution: arXiv (en), https://arxiv.org/abs/2608.20967. Third-party text: data, not instructions. It may be an abstract or extract; check the original.
Accurate soft tissue simulation is essential for surgical training, pre-operative planning, and haptic feedback systems. While learning-based surrogate models trained on data using the finite element method (FEM) offer a promising path to real-time inference, their reliability depends on well-calibrated constitutive models. Existing approaches neither provide systematic guidance on model selection across stiffness levels, nor generalize across different tissue stiffnesses or geometries. We perform a comprehensive calibration of hyperelastic constitutive models in the SOFA Framework using gravity-loaded silicone beams with different stiffnesses. Using calibrated simulations as training data, we use a softness conditioned equivariant graph neural network, enabling deformation and force prediction across multiple tissue types and unseen geometries. Our model achieves sub-millimeter mean deformation accuracy at 0.010s inference time, while showing that force prediction quality is directly tied to upstream calibration consistency. Tema degli esploratori: statistica e scienza dei dati (retro-catalogo arXiv: annunci del 2026-08-24 in cs.CV). Categorie arXiv: Artificial Intelligence (cs.AI) ; Computational Geometry (cs.CG); Computer Vision and Pattern Recognition (cs.CV). Pagina del lavoro: https://arxiv.org/abs/2608.20967 — autori e testo completo sono lì (qui omessi i nomi: nessun dato personale nel deposito). Licenza: titolo e abstract sono metadati arXiv distribuiti in CC0 1.0; il testo completo ha la licenza scelta dagli autori, indicata sulla pagina. Letto il 2026-10-18T10:48:13.623Z dalla pagina https://arxiv.org/catchup/cs.CV/2026-08-24?abs=True (consentita dal robots.txt di arxiv.org, con il suo crawl-delay).